CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Switch Configuration
Min Transmit Priority
The minimum Token-Ring frame priority that will be used for transmits. Possible
values are 0–6. The default value is 4.
Error High Threshold
This field is only valid when Forwarding Mode is set to auto, and is used to force
a port to store & forward mode when the percentage of errors detected in the
Sampling Interval is more than the error high threshold. Possible values are 0–100
percent. The default value is 10 percent.
Error Low Threshold
This field is only valid when Forwarding Mode is set to auto, and is used to return
a port to cut-through mode when the percentage of errors detected in the Sampling
Interval is less than the error low threshold. Possible values are 0–100 percent. The
default value is 1 percent.
Error Sampling Interval
This field is only valid when Forwarding Mode is set to auto, and specifies a
sampling period in minutes. The sampling period is used when counting errors to
determine a ports forwarding mode. Possible values are 1–60 minutes. The default
value is 10.
Cfg Loss Threshold
Configuration loss occurs when a port completes a connection, allows data traffic
to flow, and subsequently closes. This threshold is used to control the number of
configuration losses that can occur within the Cfg Loss Sampling Interval. When
the threshold is exceeded, the port is disabled and must be enabled via this screen
or an SNMP manager. Possible values are 1–100. The default value is 8.
Cfg Loss Sampling Interval
Specifies a sampling period in minutes. The number of configuration losses
occurring within this interval is compare to the Cfg Loss Threshold to determine
if a port should be disabled. Possible values are 1–60 minutes. The default value is
10.
➽
Note: If you change any configuration parameters of a connected port, the port will
close and reopen and you will lose all address information and statistics for that
port.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......