CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Monitoring the Network with the Console
Join State
This field displays the present state of the Join FSM. Possible values are Not
Specified, Bypass, Registration, Lobe Test, Dup Addr Check, Dup Addr Det, Join
Complete and Await Notify.
Monitor State
This field displays the present state of the Monitor FSM. Possible values are Not
Specified, Operational, Transmit Beacon, Wire Fault Delay, and Int Test Wait.
Beacon Source Address
This field displays the source address used in the last Beacon MAC frame
transmitted or received.
Beacon UNA
This field displays the value of the UNA subvector X'02' used in the last Beacon
MAC frame transmitted or received. It will indicate the individual MAC address of
the sending ring station’s nearest active upstream neighbor (NAUN). The value
could be a valid individual MAC address or Unknown.
Beacon Physical Drop Number
Physical location of the sending ring station. This field displays the value of the
Physical Drop Number subvector X'0B' used in the last Beacon MAC frame
transmitted or received. Valid range is from 0x00000000 to 0xFFFFFFFF.
Event Status
This field displays the latest event status of the TXI interface. Possible values are
Insert REQ Rec, Insert RPS Rec, Report Error, Heart Beat Lost, Signal Loss,
Beacon Received, Remove, Internal Error, Station/CPort Err, Wire Fault, Claim
Received, Purge Received, Standby Received, Invalid SA, Act Mon Recvd, Phantom
Loss, and Dup Addr Det.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......