198
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Troubleshooting
Procedure D
Use this procedure if one device connected to the switch is having a communication
problem. The ERR LED and the DIAG LEDs are off, and other attached devices
can communicate through the switch:
1. Check the port LEDs.
— If the port INSRT LED is on, the problem is probably external to the
switch. Go to Step 2.
— If the port INSRT LED is off, the port is probably disabled. Check that the
port configuration matches the attached device, and then go to Step 3.
2. If the INSRT LED on the failing port is on, and the attached device still cannot
communicate:
— If the attached device is directly connected, it might be set up incorrectly.
Go to step 4.
— In a shared environment, check the segment cabling and the media access
unit.
— If problem persists, try another identically configured port on the switch.
If the new port works there is a problem with the failed port. Obtain
service. Contact your place of purchase.
3. Do the following:
— Using the console of the SNMP manager, check to see whether the failing
port is disabled. If it is, enable it. A port will disable itself when the Cfg
Loss Threshold parameter is exceeded (see “Cfg Loss Threshold” on
page 108). This can be caused by poor cables, a faulty station connected
to the switch, or a bad port on the switch.
— If the port is not disabled, disconnect the port cable. Try moving the cable
to another port until service can be arranged. If the switch can be
temporarily removed from service, connect a console and reset the switch
with diagnostics to see whether the port passes diagnostics and initializes.
If it does not, the problem is in the switch. In this case, contact technical
support as described in Chapter 11, “Getting in Touch with Technical
Support”.
4. Restart communications program on the failed connected device.
— If the communication program appears to start without errors, observe the
INSRT LED on the switch port. If it is on, the problem may have gone
away. Check the Cfg Loss Threshold parameter in the Port
Configuration screen (page 105) for possible causes of the failure.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......