46
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Preparing for Installation
Site Requirements
Following are the site requirements for installation.
Environment
Choose a clean, dust-free, (preferably) air-conditioned location. Avoid direct
sunlight, heat sources, or areas with high levels of EMI (Electromagnetic
Interference).
Chassis Accessibility
Make sure the front and back panel of the equipment is accessible so that you can
monitor the LED indicators and access the control switches. Leaving enough
clearance at the front and back will also allow easier cabling and service.
Cooling and Airflow
Two fans, which are located at the left side of the switch, cool the interior by
drawing air through vents on the left side and forcing heated air out through holes
in the right side. If the internal temperature exceeds 50°C (112°F), a temperature
error is reported to the console.
➽
Caution: To protect the equipment from overheating, do not operate it in an area
that exceeds the maximum recommended ambient temperature of 40°C (104°F). To
prevent airflow restriction, you must allow at least 7.6 cm (3") of clearance around
chassis openings for proper airflow.
Power
The source electrical outlet should be installed near the switch, be easily accessible,
and be properly grounded.
Also, observe the following power cable considerations before you begin
installation of the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605
Token-Ring Fiber Switch.
1. The socket outlet shall be installed near the equipment and shall be easily
accessible.
2. To prevent electrical shock, the power cord set used must comply with national
regulations.
2a. The female receptacle of the cord must meet CEE-22 requirements.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......