
53
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Preparing for Installation
The Next Step
Typically, the first point of congestion in this newly configured network would be
the servers. Because the usual mode of operation for a Token-Ring adapter is half-
duplex, the servers can either send or receive information with one other segment
attached to the switch. If the server adapters are replaced with full-duplex adapters,
such as the Olicom OC-3118 or the Olicom OC-3137, and are attached as single-
station segments as shown in Figure 11, they can send and receive data
simultaneously. The capacity of each server is now 32 Mbps per port.
However, network congestion is not always at the backbone level. In Figure 12, the
two MAUs and six bridges have been replaced by a single switch. Internally, the
switch is configured with one BRF and seven CRFs, allowing the switch to replace
the MAUs and bridges without the need for further reconfiguration. This
configuration greatly improves performance by allowing switching directly from
ring to ring. The four servers, each with a full-duplex connection to the switch, have
been grouped in CRF 5.
If even better performance is needed, the switch shown in Figure 12 can be replaced
with a stack of switches. A stack can provide up to 224 ports, making it feasable to
connect workstations directly to a switch port. A direct connection provides a
dedicated 32 Mbps for users with high bandwidth requirements.
Figure 12. Replacing SRBs with CrossFire 8600 or CrossFire 8605
1
2
CRF 2
3
CRF 3
7
CRF 7
8
CRF 8
9
CRF 9
Server
Switch
CRF 5
Server
Server
Server
32 Mbps
CRF 1
BRF
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......