CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Preparing for Installation
2b. The cord must be UL listed, CSA labelled, and consist of three conductors
with a maximum of 15 feet in length. Type SVT or SJT cord sets shall be
used for units which stand on a desk or table. Type SJT cord sets shall be
used for units which stand on floor.
2c. The male plug for units operating at 115 VAC shall consist of a parallel
blade, grounding type attachment plug rated 15 A, 125 VAC.
The male plug for units operating at 230 VAC shall consist of a tandem
blade, grounding type attachment plug rated 15 A, 250 VAC.
The male plug for units operating at 230 VAC (outside of the United States
and Canada) shall consist of a grounding type attachment plug rated 15 A,
250 VAC and have the appropriate safety approvals for the country in which
the equipment will be installed.
➽
Caution: Support the CrossFire 8600 Token-Ring Switch and/or the CrossFire
8605 Token-Ring Fiber Switch while you are installing the unit to avoid dropping
it on the floor or any equipment beneath it in the rack. The CrossFire 8600 Token-
Ring Switch unit and the CrossFire 8605 Token-Ring Fiber Switch unit each
weighs approximately 8.8 kg (19.4 lbs).
➽
Caution: To separate the switch from the power, pull the power cord completely
out from the socket. The power socket must be easily accessible and located near
the unit.
➽
Warning: All RJ-45 connectors must only be connected to safety extra low voltage
(SELV) circuits like local area networking (LAN).
➽
Warning: This product relies on the building’s installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger than
120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors
(all current-carrying conductors).
➽
Warning: A voltage mismatch can cause equipment damage and may pose a fire
hazard. If the voltage indicated on the label is different from the power outlet
voltage, do not connect the chassis to that receptacle.
➽
Caution: If you are using the redundant power supply unit CrossFire 8311 note that
this unit is not hot-swappable. Both the CrossFire 8311 unit and the switch must
be off before connecting or disconnecting the DC power cable.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......