Monitoring the Network with the Console
Board Temperature
Indicates whether the switch is operating at normal or unacceptably high (over
50°C (122°F)) temperatures. The actual board temperature is also shown.
Frames Transmitted
Number of frames transmitted by the CPU of the switch.
Frame Transmit Errors
Number of errors recorded (by the CPU) when attempting to transmit frames.
Frames Received
Number of frames received (by the CPU).
Error Frames Received
Number of frames received (by the CPU) that were corrupted or have CRC errors.
Frames Lost
Number of frames dropped (by the CPU) due to exceeding the capacity of the
software buffers.
Pending Send Requests
Number of software transmitted packets that are waiting for queues to hardware.
Currently Active Stations
Number of entries in the address table, representing the number of currently active
stations (MAC addresses), or nodes, on all ports of the switch.
Largest Number of Stations
The most stations (MAC addresses) ever active on all ports at one time since the
last reset or power cycle.
Maximum Address Table Chain
Largest number of MAC addresses that have hashed to the same location in the
lookup tables. Used for technical system evaluation and troubleshooting.
Address Table Full
Number of times the hash table reached capacity. Used for technical system
evaluation and troubleshooting.
Reset
Resets the switch statistics on this screen.
Содержание CrossFire 8600
Страница 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Страница 2: ......
Страница 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Страница 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Страница 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Страница 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Страница 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Страница 208: ...192 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Monitoring the Network with SNMP...
Страница 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Страница 222: ...206 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Getting in Touch with Technical Support...
Страница 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Страница 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Страница 249: ......