WIRELESS H2S TRANSMITTER (WT SERIES) - USER GUIDE
2.
Battery Life Expectancy
Users can set two separate reporting intervals: one for the normal
transmission cycle (> 60seconds) and the other being a faster burst mode
(between 30 and 60 seconds) when the transmitter is in an alarm state.
In addition, the H2S Transmitter continuously supplies power to the sensor
to monitor changes in H2S levels regardless of the reporting intervals.
Therefore, refer to the battery life expectancy data below to select the
most appropriate reporting interval for your application.
Tx Interval in Minutes Tx Interval in Seconds
Battery Life (Years)
1
60
2.35
2
120
3.38
3
180
3.95
4
240
4.3
5
300
4.54
10
600
5.11
15
900
5.32
60
3600
5.67