7. Troubleshooting and repair procedure
Check item
Check work
Action to be taken
at NG
(1-1-5) LSI operation check
I/F signal supplied
from the PU board
to the Operator
Panel board.
Check if the signal is output to the OPE
connector of the PU board or not.
Pin-7: Send data (Sending data from the PU
board)
Pin-9: CLR
If it is normal, the signal is output always.
Replace the PU
board.
I/F signal supplied
from the PU board
to the Operator
Panel board.
Check if the signal is output to the OPE
connector of the PU board or not.
Pin-6: Send data (Sending data from the PU
board)
If it is normal, the signal is output always.
Replace the
Operator Panel
board.
(1-3) Error messages related to Operator Panel are displayed.
Check item
Check work
Action to be taken
at NG
(1-3-1) Error message
Error message
Check the error contents by referring to the Error
Message List.
Follow the
instruction.
(1-4) "RAM check in progress" or "Initializing" display is kept appearing.
Check item
Check work
Action to be taken
at NG
(1-4-1) Operator Panel display freezes.
Operator Panel
display
"RAM check in progress" or "Initializing" display
is kept appearing.
Replace the
ROM DIMM of
CU, or replace
the CU board.
Remove the
optional RAM
and HDD. Then
perform the
check.
If the check
result shows
NG, replace the
CU board.
Note!
Note!
However, for the Data Protection Kit –A1, refer to section 7.8.
(1-2) PLEASE WAIT
(If the message is left attended, the error number changes to "COMMUNICATION ERROR".)
Check item
Check work
Action to be taken
at NG
(1-2-1) Check installation condition of printed circuit board
Connection
condition of the PU
board and CU board
Check the connection condition of the CU IF
connector of the PU board, and check that of
the FFC connector of the CU board.
Connect the
FFC normally.
(1-2-3) Implement version upgrade of the PU firmware
Version upgrade of
the PU firmware
When the PU firmware version upgrade is
completed, this display appears.
Check the PU firmware version number by using
the menu print or the maintenance function.
If the message
reappears after
the power is re-
started again,
implement the
confirmations of
sections (1-3-1)
and (1-3-2).