CHAPTER 1
GETTING STARTED
7000 Series T72XW Indicator Service Manual
1-7
Ohaus Corporation www.ohaus.com
1.6.2 COM1 Serial Port Connections
The COM1 port provides an RS-232 connection for external serial devices. Figure 0- indicates
which terminal carries which signal on the COM1 port. Make the connections as necessary.
Terminal
Signal
TxD
Transmit RS-232
RxD
Receive RS-232
Gnd
Logic Ground
Figure 0-4: COM1 Port Signal
An example of connecting via RS-232 to external equipment is shown in Figure 0-. Make the
connections as necessary.
NOTES:
1. USE ONLY SHIELDED CABLE.
2. MAXIMUM CABLE LENGTH: 50 FEET (15 METERS).
3. WIRE SIZE: 18 AWG (.823 mm
2
) MAXIMUM
24 AWG (0.205 mm
2
) MINIMUM.
Figure 0-5: Sample COM1 Connections