92
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
Output
Offset Length
[Byte]
Bit
Offset
Type
Data
Description
4
1
0
Version
The protocol’s version.
5
1
0
bool
Ready
active when ready for closure/pincer test or for
receiving commands.
1
bool
system error
active when serious errors have occurred. error
must be acknowledged first, in order to continue
working with the ePC 01.
2
bool
Pincer test
active during the pincer test. see pincer test
status for sub-status information.
3
bool
Closure
active during closure. see stepbystep status for
sub-status information.
4
bool
n/a
5
bool
Input of nominal force
permitted
active when the ePC 01 is ready to accept the
measured nominal force.
6
bool
n/a
7
bool
Toggle bit
Toggles every 1024 ms.
6
2
Int
aPn no.
Currently selected aPn no.
8
2
Int
seQ no.
Currently selected seQ no.
10
2
Int
error number
error number, current error shown on the display.
12
1
sint
stepbystep-status
step by step status according to coding. see
Code Definitions->stepbystep status codes.
13
1
sint
Pincer test status
Pincer test status according to coding. see Code
Definitions->Pincer test status codes.
14
4
string
Trigger Unit Type
Type of the Trigger Unit.
18
4
string
Trigger Unit article no.
article number of the Trigger Unit.
22
4
string
Pincer Head article no. saved for article number of the pincer head.
26
1
sint
Closing mode
force-Prio=1, stroke-Prio=2
27
1
0
bool
oK
active if last closure function was oK.
1
bool
no
active if last closure function was not oK.
2
bool
Hold
active when the measurement values of the hold
function are available. The hold and detect func-
tions can never be active together.
3
bool
Detect
active when the measurement values of the
detect function are available. The hold and detect
functions can never be active together.
4
bool
Contact
active when the measurement values of the con-
tact function are available.
5
bool
Closure
active when the measurement values of the clo-
sure function are available.
6
bool
Verification
active when the measurement values of the verifi-
cation function are available.
7
bool
n/a
28
4
float
Holding/detecting clo-
sure gap setpoint
Target gap during the holding or detecting func-
tion at the time of the last closure.
32
4
float
Holding/detecting clo-
sure gap tolerance (-)
negative tolerance of the target gap during the
holding or detecting function at the time of the
last closure.
36
4
float
Holding/detecting clo-
sure gap tolerance (+)
Positive tolerance of the target gap during the
holding or detecting function at the time of the
last closure.