Error message
Cause of the error
Troubleshooting measures
PE7008
The verification force was outside the
tolerance range:
•
The verification force tolerance
chosen was set too tight
•
selected verification force too
low
•
excessive friction in the system
(pincer and pincer head)
Perform actions in the following sequence until the
error is eliminated:
►
Proceed with the pincer test.
►
Check the verification force tolerance and in-
crease it if necessary.
►
Increase the verification force, but do not exceed
500 n.
►
send in the pincer and have it serviced.
PE7009
The verification value was outside
the tolerance range:
•
Clamp not hooked in or locked
•
The pincer slipped off the clamp
during the verification function
•
The verification gap tolerance
was set too tight
•
excessive friction in the system
(pincer and pincer head)
Perform actions in the following sequence until the
error is eliminated:
►
Check the clamp engagement and repeat the
closure with a new clamp.
►
Proceed with the pincer test.
►
Check the verification gap tolerance and increase
it if necessary.
►
send in the pincer and for servicing.
PE7010
Verification force and verification val-
ue were outside the tolerance range:
•
Pincer jaws have not verified on
the closing mechanism (pincer
was removed before verification)
•
The verification force was set
too low
•
The verification force tolerance
chosen was set too tight
•
The verification gap tolerance
was set too tight
Perform actions in the following sequence until the
error is eliminated:
►
Check the insertion of the clamp.
►
Proceed with the pincer test.
►
Check the verification force and increase it if nec-
essary, but do not exceed 500 n.
►
Check the verification force tolerance and in-
crease it if necessary.
►
Check the verification value tolerance and in-
crease it if necessary.
►
send in the pincer and have it serviced.
PE7011
Clamp snap-in not detected:
•
The clamp did not travel past the
hook
•
The clamp snapped in outside
the closing gap tolerance win-
dow
•
The snapping force was too
weak to be detected
Perform actions in the following sequence until the
error is eliminated:
►
Check the closure gap tolerance and increase it if
necessary.
►
Check the type of clamp.
►
Check the snap Detection speed Threshold
(contact local oeTIKeR service Center).
PE7012
Pincer test canceled by user
►
Repeat the pincer test.
PE7013
Pincer does not move to the open
starting position:
•
The friction in the pincer is too
great
•
exhaust air vents blocked.
•
Incorrect initial position due to
error
PE7015
Perform actions in the following sequence until the
error is eliminated:
►
Proceed with the pincer test.
►
Clean the exhaust air vents.
►