61
OETIKER EPC 01
oPeRaTe THe ePC 01 VIa an eXTeRnal ConTRol UnIT (PlC)
Issue 11.22
08905306
9
Operate the EPC 01 via an external Control Unit (PLC)
DANGER
Risk of serious injury when operating the EPC 01 via an external Control Unit!
Unintentional closures may occur due to system errors.
During operation, there is a serious risk of injury due to crushing, laceration and shearing of fin-
gers by the moving jaws on the pincer head.
►
The system integrator is responsible for the safe integration of the ePC 01.
►
The system integrator must perform a risk assessment and set up the tool according to this
analysis.
►
The integration shall only be carried out by qualified personnel.
►
If you have any questions about the integration, please contact oeTIKeR.
9 1 Description of the integration for semi/fully automatic mode
9 1 1 Instruction of Incorporation
The standard version (delivery condition) of the ePC 01 is designed as a complete machine with valid Ce confor-
mity.
NOTICE
When operating the EPC 01 in semi/fully automatic mode via an external control, the
closing process is controlled or triggered by an external Control Unit (PLC) In this case,
the product operated in semi/fully automatic mode is therefore considered to be an incom-
plete machine!
The valid declaration of incorporation for semi/fully automatic mode is provided with the pur-
chase of the corresponding license for the release of semi/fully automatic mode.
►
for a safe integration, it is imperative that the instruction of incorporation is read and ob-
served in their entirety.
►
oeTIKeR accepts no liability for ePC 01 units controlled by third parties.
►
all personal injury and damage to property resulting from improper use is the responsibility not of the manu-
facturer but of the operator of the ePC 01.
►
The relevant accident prevention regulations and other generally recognized safety-related legal regulations
must be observed.
►
Unauthorized modifications to the ePC 01 exclude any liability of the manufacturer for resulting damage.