TRoUblesHooTInG anD eRRoR MessaGes
Issue 11.22
08905306
Error message
Cause of the error
Troubleshooting measures
HE4009
Wrong gap gauge inserted
Perform actions in the following sequence until the
error is eliminated:
►
Perform the calibration step again using the cor-
rect gap gauge.
►
abort the pincer test and start again.
HE4010
license for demo version expired
►
enter valid license (Customer admin).
HE4011
Invalid or no license present on the
Control Unit
►
enter valid license (Customer admin).
HE4012
elK pincer was used:
Pincer type is not covered by the
current existing license
►
enter valid license that includes elK clamps
(Customer admin).
►
Replace the elK pincer with an ePC 01 pincer
HE4013
safety lever was not fully actuated
when triggering the closure or the
pincer test
►
fully actuate the safety lever and perform the clo-
sure or the pincer test again.
HE4014
The safety lever was released during
the closure process or during the
pincer test
►
Keep the safety lever fully depressed during the
entire closure process (incl. retraction of the pin-
cer).
HE4015
safety lever was not released after
more than 20 consecutive closures
►
Check safety lever for blockage and remove the
blockage if necessary.
►
During 20 consecutive closures, release the safety
lever at least 1 time.
►
send in the pincer and have it repaired.
HE4016
elK 02 Trigger Unit without safety
lever is connected
►
Replace the elK 02 Trigger Unit with an ePC 01
Trigger Unit with a safety lever.
HW5001
Max. number of closures until the
recommended pincer test has been
reached
►
Proceed with the pincer test.
►
alternatively, set the number of closures as
required in the Control Unit settings / pincer test
menu.
HW5002
The force correction exceeds the
factor 2 to the default setting
►
ensure that the force has been transmitted cor-
rectly. If necessary, end the pincer test and start
again.