13 1 4 System capability within the working temperature range
Force priority closure
Gap priority closure*
Ho 2000 to Ho 4000
± 150 n
± 0.2 mm
Ho 5000
± 250 n
± 0.2 mm
Ho 7000
± 250 n
± 0.2 mm
Ho 10000
± 300 n
± 0.2 mm
CmK value
≥ 1.67
* The accuracy of travel (gap of the pincer) is ensured in the operative range of the clamp. because the pincer
head movement is radial, larger deviations outside the operative range may occur.
13 1 5 Compressed air
General technical data
Parameter
Value
air quality
≤ 5 µm, must not contain oil or water (Iso 8573-1)
air volume
up to 2 l / closure
Compressed air inlet pe
> 4 bar to max. 10 bar (6 bar recommended)
Compressed air connection specification
Connection
Specification
Compressed air inlet pe
Push-in connector for hose 8/6 mm
Compressed air output pa
Compressed air reservoir specification
Parameter
Value
Volume
2 to 5 ltr depending on the size of the pincer
13 1 6 Lubricant
Type
Type
Manufacturer
OETIKER Part no
Grease
RenolIT lX 2
fUCHs sCHMIeRsToffe GmbH
friesenheimer strasse 19
D-68169 Mannheim
49 621 3701-0
fax +49 621 3701-7000
08901490
Grease for
medical
applications
MoToReX fooD GRease Cs-Hs 2 MoToReX aG
bern-Zürich-strasse 31
CH-4901 langenthal
Tel. +41 (0)62 919 75 75
08906058