91
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
13 3 5 Mapping list
Input
Offset Length
[Byte]
Bit
Offset
Type
Data
Description
0
1
0
bool
functions Menu
navigate to the functions selection menu.
1
bool
aPn Menu
navigate to current aPn menu. a closure process
can only be started from here.
2
bool
sequence Menu
navigate to sequence Menu. from this menu a
closure can be started and if this is oK, then the
next aPn is loaded automatically.
3
bool
Pincer test menu
navigate to Pincer test menu. a pincer test can
only be started from here.
4
bool
start
starts a closure or in the pincer test/stepbystep
the corresponding pincer test step. Value must be
reset to effect a restart. The enable function must
be active.
5
bool
Canceled
abort a started closing function.
6
bool
acknowledge error
acknowledge error.
7
bool
Confirm the force test
Confirm the force test and then move to the next
test.
1
1
0
bool
enable
safety control bit to ensure that a closure was not
started accidentally.
1
bool
apply aPn
To be activated when the aPn number is to be
input and applied.
2
bool
apply sequence no.
To be activated when the sequence number is to
be input and applied.
3
bool
apply nominal force
To be activated when the nominal force is to be
input and applied.
4
bool
n/a
5
bool
n/a
6
bool
n/a
7
bool
n/a
2
2
Int
applicable aPn
selects the current aPn. aPn number must be
> 0 and the aPn settings must correspond the
locked pincer. active only in the «Ready» status
and in the aPn menu.
4
2
Int
applicable sequence
selects the current sequence. sequence num-
ber must be > 0 and the aPn settings must
correspond the locked pincer. only active in the
«Ready» status and in the sequence menu.
6
2
Int
Measured nominal
force
applies the measured nominal force. The nominal
force must be > 0. only active during the pincer
test and when the «nominal force input allowed»
flag is active. Can only be set 1x / force test
closure.
8
110
---
n/a