WoRKInG WITH THe ePC 01
Issue 11.22
08905306
6 4 EPC 01 feedback
The feedback of the system can be read out via the following channels (oK/noK).
•
When the button
START
on the Trigger Unit or the leD above the rotary pushbutton on the Control Unit
–
Continuous green signal: system is oK
–
blinking red signal: error (for exact error identification check the error message-number on the display of
the Control Unit
•
Via the interfaces, depending on the configuration of the PC software (
6 5 Changing the pincer
WARNING
Risk of injury from escaping compressed air!
►
When changing the pincer, switch off the Control Unit.
1. switch the Control Unit off.
2. Vent the Control Unit.
3. Disassemble the pincer:
–
Disconnect the pneumatic plug of the hybrid hose from the compressed air outlet
pA
.
–
Disconnect the electrical plug of the hybrid hose from the connection
X1
.
–
Remove the pincer.
4. Mount the new pincer:
–
Connect the electrical plug of the hybrid hose to the connector
X1
. secure the plug-in connection
finger-tight with both screws.
–
Connect the pneumatic plug of the hybrid hose to the compressed air outlet
pA
.
5. switch on the Control Unit.
6. Proceed with the pincer test (
).
6 6 Set EPC 01 out of operation
If the ePC 01 is not going to be used for an extended period of time it must be taken out of operation and then
stored.
9
ePC 01 switched off.
1. Disconnect the ePC 01 from the compressed air and voltage supply.
2. Depressurize the ePC 01.
3. Disconnect the cables and hose connections.
4. Remove the components.
5. storing the ePC 01 (
NOTICE
When the ePC 01 is put back into operation having been taken out of operation, the activities
must be carried out as for a new purchase (