64
OETIKER EPC 01
MaInTenanCe anD RePaIR
Issue 11.22
08905306
10 3 3 Checking and changing the pre-filter
Inspect the pre-filter at regular intervals for soiling and replace if necessary
Recommended filters, pre-filters and accessories:
Designation
Manufacturer, type
Part no
filter
oeTIKeR, standard filter with sieve function ≤ 5μ
05005930
filter
fesTo, Type Ms4-lf-1/4-C-R-V
529 397
Pre-filter (for heavily polluted air)
fesTo, Type Ms6-lf-1/4-e-R-V
527 668
bracket for fesTo filter
fesTo, Ms4-Wb or Ms6-Wb
–
9
Maintenance prepared.
1. Check the pre-filter for contamination.
2. Change the pre-filter in the event of contamination. Install the new pre-filter vertically to ensure proper opera-
tion.
3. Completion of maintenance (
10 3 4 Have the pincer and pincer head serviced (recommended)
oeTIKeR recommends that the pincer and the pincer head are sent to the local oeTIKeR service Center
(
) for servicing after the specified interval.
a counter is integrated in the Trigger Unit of the clamp, which after 250,000 closures issues a warning to the Con-
trol Unit that maintenance is due.
9
Maintenance prepared.
1. Disassemble the pincer and pincer head, send them in and have them serviced.
2. after maintenance, install the pincer and pincer head.
3. Completion of maintenance (
10 4 Repair
10 4 1 Changing the pincer head
WARNING
Risk of injury when the pincer head is not mounted!
starting a closure can cause the compression spring and plunger to fly apart if the pincer head is
not mounted.
►
never operate the pneumatic pincer unless the pincer head is mounted.
►
Change the pincer head only when the power supply and compressed air supply are discon-
nected.