84
OETIKER EPC 01
aPPenDIX
Issue 11.22
08905306
Pin assignment
Pin
Assignment
Pin
Assignment
1
24 V ±10% (supply voltage)
14
bit 32 input
2
Reset input
15
bit 64 input
3
enable input
16
spare input
4
Quit / function input
17
busy output
5
start input
18
system error at output
6
spare input
19
Pincer test output
7
function input
20
Ready output
8
spare input
21
oK output
9
bit 1 input
22
output not oK
10
bit 2 input
23
Trigger signal
11
bit 4 input
24
spare output
12
bit 8 input
25
GnD
13
bit 16 input
Housing Pe (protective earth conductor)
Pin assignment Function Description
Times
Reset
Input
•
Cancels a closure function that was started
•
Cancels the pincer test
Impulse > 300 ms
enable
Input
enable with start function
start
Input
Triggering the start function (only if enable=TRUe pos-
sible)
> 100 ms
function back
Input
skip back to the «function» display
error pending
•
acknowledging errors
at
Function
display (start screen)
•
Request pincer test
•
skip to the selected aPn *
•
skip to seQ
at aPn display
•
skip to main menu (start screen)
at pincer test
•
Confirm the force test
•
skip to main menu (start screen)
•
2 s
•
2 s
•
4 s
•
6 s
•
4 s
•
2 s
•
4 s
bit 1 ... bit 64 *
Input
selecting the aPn
noTe: The sum of the bits determines the aPn
example: aPn 40 = bit 8 = TRUe + bit 32 = TRUe
Continuous signal
busy
output
active during the crimping process
–
system error
output
active in the event of an error message
–
Ready
output
active: Close is enabled
–
Trigger signal
output
after each closure step
(Configurable via PC software)
–
* The aPn is selected via the inputs «Input bit 1» .. «bit 64 input»