English 14
English
HF TIG
When the mode pushbutton is in HF TIG position, the
machine is ready for HF TIG welding. During the HF
TIG mode, the TIG arc is started by HF without pressing
the electrode on the work piece. The HF used for
starting the TIG arc will remain on for 3 seconds; if the
arc is not started in this time limit, the trigger sequence
must be restarted.
NOTE
: The HF start strength is adjusted to the
tungstensize and type, which can be selected in menu
GTAW.
AC Tig Welding
To start AC Tig welding process:
1.) Set polarity
2.) To select AC Tig welding:
Process
Visualization
Lift
HF
Press MODE several times until the LED above lights up
2T led is turned on for default.
Ac wave shape section is available. About Lift and Tig
starting see section above.
Tig Welding Sequences
During no welding operation at each pressure of SEL
push button, it’s possible to step through all sequencer
and set parameters.
During welding the Sel pushbutton is enabled for the
following functions:
Output
current
Only if Pulse Function is active: is possible operates
on the values of Duty (%), Frequency (Hz) and
Background current (A).
The new parameter value is automatically saved.
TIG Trigger Sequences
TIG welding can be done in either the 2-step or 4-step
mode. The specific sequences of operation for the
trigger modes are explained below.
Legend of the symbols used:
Torch Pushbutton
Output Current
Gas Pre-flow
Gas
Gas Post-flow
2-Step Trigger Sequence
To select 2-Step sequence:
Output
Visualization
Press several times until the LED above lights up
With the 2-step trigger mode and a TIG welding mode
selected, the following welding sequence will occur.
1. Press and hold the TIG torch trigger to start the
sequence. The machine will open the gas valve to
start the flow of the shielding gas. After the preflow
time, to purge air from the torch hose, the output of
the machine is turned ON. At this time the arc is
started according to the selected welding mode. The
initial current is set to 25A for LIFT starting (starting
current parameter is disabled in the sequencer) or
set according to the Starting current parameter for
HF starting. After the arc is started the output
current will be increased at a controlled rate, or
upslope time, until the Welding current is reached.
If the torch trigger is released during the upslope
time the arc will stop immediately and the output of
the machine is turned OFF.
2. Release the TIG torch trigger to stop welding. The
machine will now decrease the output current at a
controlled rate, or downslope time, until the Crater
current is reached and the output of the machine is
turned OFF.
After the arc is turned OFF, the gas valve will remain
open to continue the flow of the shielding gas to the
hot electrode and work piece.
Содержание CITOTIG 315
Страница 2: ......
Страница 333: ...I 12 05 1 2 4 5 7 Waste Electrical and Electronic Equipment WEEE 28 28 REACh 28 28 28 29...
Страница 337: ...4 01 11 IEC 61000 3 12 Ssc 2227 Ssc 2227 A...
Страница 338: ...5 01 11 Oerlikon CE 2006 25 EC EN 12198 2 15 EN169...
Страница 339: ...6 30 HF TIG GTAW TIG GTAW 85 8...
Страница 341: ...8 Stick DC DC AC TIG GTAW TIG TIG TIG COOLER 4 COOLER Stick COOLER COOLER REMOTE LED A B C F A N Fan As Needed 10...
Страница 342: ...9 COOLER COOL SYS 30 6 7 D TIG E COOLER 400 COOLER Power ON TIG...
Страница 344: ...11 1 2 2 4 3 TIG AC AUTO AC WAVESHAPE AUTO AUTO ON AUTO OFF AC WAVESHAPE AUTO AUTO AUTO ON 1 2 3 TIG TIG AC DC Sel...
Страница 345: ...12 5 A 9 1 2 1 M 1 SAVE 2 M 2 RECALL 3 M 3 MEM SET 3 3 3 MEM SAVE 1 2 3 3...
Страница 348: ...15 TIG TIG 2 4 2 2 2 TIG 1 TIG 25 LIFT 2 TIG 2 2 2 GTAW 2RST 2...
Страница 349: ...16 1 2 4 4 4 1 LIFT 25 A 1 2 2 3 4 TIG 3 4 4 4 GTAW 4RST 4 3 4 1 2...
Страница 350: ...17 3 4 2 3 3A TIG 3 4 3 TIG 3 TIG GTAW GTAW TIG 2S 2 S 0 0 0 SEL SPT SPT 0 100...
Страница 351: ...18 Set A2 GTAW BILV TIG 4S B 0 0 4S 1 2 3 Set A2 3A 2 SEL A2 2 TIG LIFT TIG ON TIG ON...
Страница 356: ...23 MANL TSTR Tig C 2S 4S GTAW...
Страница 358: ...25 SYS SYS SYS UNIT VRD VRD LED X TIG RMTE A TO A TO COOL CTRL UI UI s ERR 105 HOUR 55 CNT RSET...
Страница 359: ...26 TIG SYS amptrol footpaddle AMP amptrol FOOT footpaddle AMP FOOT AMP ON AUTO IDLE OFF 01 02 03 06 09 11 12...
Страница 428: ...Spare Parts Electrical Schematic Spare Parts Electrical Schematic 6 Electrical Schematic CODE 50406...
Страница 429: ......