English 11
English
Sequencer Functions:
The sequencer allows for the customization of the TIG
welding operation both in AC & DC- polarities. Pressing
the “Sel” button will cycle through the process graph.
Pre-Flow
: Sets the time in
seconds gas will flow prior to arc-
start initiation
Starting Current
: Sets the
starting amperage for the
process.
Initial Slope
: Sets the time in
seconds it takes the starting
current to reach normal operating
amperage.
Operating Amperage
: Sets the
amperage for all welding process
permitted.
Final Slope:
Sets the time in
seconds it takes the operating
amperage to ramp down to the
Finishing current.
Finishing Current:
Sets the
finishing amperage for the
process.
Post Flow:
Sets the time in
seconds gas will flow after the arc
is terminated
Pulse Sequencer Functions:
Percent Peak Current:
This
functions sets the amount of
time the pulse waveform spends
at the peak current setting. This
function is set as a percentage
of the total time for the pulse
cycle.
Pulses-Per-Second:
Sets the
total number of pulse cycles per
second of time.
Percent Background Current:
Sets the background amperage
of the pulse waveform.
Background amperage is set as
a percentage of the peak
current.
Main Amperage Control:
The main amperage control button is intended to be a quick
selection method to adjust the main amperage setting. This
function will allow users to quickly exit the sequencer
portion of the U/I, eliminating the need to cycle through all
possible sequencer functions to adjust the main amperage
or exit the sequencer menu.
This knob is also a multi-purpose command: see the
“Operating Instruction” section for a description of how to use
this command for parameter selection.
Displays:
The right meter displays the preset welding current (A) before
welding and the actual welding current during welding, and
the left meter shown the voltage (V) at the output leads.
A flashing on both displays indicate that the value read is the
average value of the previous welding operation. This
feature shown the average value for 5seconds after every
welding time.
If a remote control is connected (the Remote LED is ON), the
left meter (A) indicates the preset and the actual welding
current following the instruction explained in the “Remote
LED” description above.
The dispays are used to indicate during setting of
parameters, the name and the value of them. Also are used
for menu indication and error codes displaing.
Содержание CITOTIG 315
Страница 2: ......
Страница 333: ...I 12 05 1 2 4 5 7 Waste Electrical and Electronic Equipment WEEE 28 28 REACh 28 28 28 29...
Страница 337: ...4 01 11 IEC 61000 3 12 Ssc 2227 Ssc 2227 A...
Страница 338: ...5 01 11 Oerlikon CE 2006 25 EC EN 12198 2 15 EN169...
Страница 339: ...6 30 HF TIG GTAW TIG GTAW 85 8...
Страница 341: ...8 Stick DC DC AC TIG GTAW TIG TIG TIG COOLER 4 COOLER Stick COOLER COOLER REMOTE LED A B C F A N Fan As Needed 10...
Страница 342: ...9 COOLER COOL SYS 30 6 7 D TIG E COOLER 400 COOLER Power ON TIG...
Страница 344: ...11 1 2 2 4 3 TIG AC AUTO AC WAVESHAPE AUTO AUTO ON AUTO OFF AC WAVESHAPE AUTO AUTO AUTO ON 1 2 3 TIG TIG AC DC Sel...
Страница 345: ...12 5 A 9 1 2 1 M 1 SAVE 2 M 2 RECALL 3 M 3 MEM SET 3 3 3 MEM SAVE 1 2 3 3...
Страница 348: ...15 TIG TIG 2 4 2 2 2 TIG 1 TIG 25 LIFT 2 TIG 2 2 2 GTAW 2RST 2...
Страница 349: ...16 1 2 4 4 4 1 LIFT 25 A 1 2 2 3 4 TIG 3 4 4 4 GTAW 4RST 4 3 4 1 2...
Страница 350: ...17 3 4 2 3 3A TIG 3 4 3 TIG 3 TIG GTAW GTAW TIG 2S 2 S 0 0 0 SEL SPT SPT 0 100...
Страница 351: ...18 Set A2 GTAW BILV TIG 4S B 0 0 4S 1 2 3 Set A2 3A 2 SEL A2 2 TIG LIFT TIG ON TIG ON...
Страница 356: ...23 MANL TSTR Tig C 2S 4S GTAW...
Страница 358: ...25 SYS SYS SYS UNIT VRD VRD LED X TIG RMTE A TO A TO COOL CTRL UI UI s ERR 105 HOUR 55 CNT RSET...
Страница 359: ...26 TIG SYS amptrol footpaddle AMP amptrol FOOT footpaddle AMP FOOT AMP ON AUTO IDLE OFF 01 02 03 06 09 11 12...
Страница 428: ...Spare Parts Electrical Schematic Spare Parts Electrical Schematic 6 Electrical Schematic CODE 50406...
Страница 429: ......