INST
ALLA
TION
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
17
3.3
Bipolar cable connection
The assembly of the power supply cable must be performed only by professional staff, in
compliance with all the safety requirements of the laws and regulations in force in the country
of use.
Carry out operations on the bench, with all elements detached from energy sources. Never
operate on potentially active components.
If necessary, disassemble the support. Unscrew the cable clip nut of the bulkhead coupling and remove it from
the fixture.
Cut the cable to the desired length: the cable length shall be sufficient to allow the connection of the device on
the type of support envisaged in the installation project. The length L of the cable must be approximately 150 mm
greater than the height H of the support.
Remove an initial section of the sheathing of the cable to allow subsequent connection to the terminals and insert
the cable in the connection coupling through the gasket.