ADJUSTMENTS AND
MAINTENANCE
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
44
Remove the JUMPER from the JM1 pins present on the resinated body.
Power the fixture and check that the LED light up correctly. Interrupt the test feed and disconnect the fixture.
Reassemble the unit. The device now is ready for the installation on the runway.
The fixture will self-calibrate during the first test ignition of the circuit: keep the circuit powered
with a constant current of 6.6 A for at least 10 consecutive minutes.