ADJUSTMENTS AND
MAINTENANCE
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
43
Monitoring reset
If the fixture is equipped with monitoring device, restore the monitoring circuit before
proceeding to close the fixture.
Unscrew the two captive screws and open the rear cover. Remove the resinated electronic unit, paying attention
not to damage the cables and the internal connections of the fixture.
Access the internal resinated body. Position the JUMPER on the JM1 pins present on the resinated body.
Connect with a supply cable to the fixture and connect the unit to the supply test. Set the current to 4.1 A (step 3).
Power the fixture and wait that the LED D13 switches off. Interrupt the supply test.