Pay particular attention to the disconnection phase of the power cable of the LED module (1). According to the
version the positioning of the connectors may differ.
In case of damage, replace the power cable of the LED module.
Do not reconnect connectors or damaged cables.
Unthread the supply cables (2) of the fixture from the support of the LED module. Disconnect the ground cable (3)
from the terminal block positioned inside the support of the LED module. If present, unthread the supply cables of
the resistance of the arctic kit (4) from the support of the LED module.
Check that the Driver Board spare part matches the component installed on the fixture.