Technical data
372
A29246-X20-X-4-7680 / faA01.fm
Environmental conditions
Operating ranges
Cooling and fresh air, air cleanliness
To maintain the thermal equilibrium for climatic class 3K2 (general office climate) in the
printing system location, a combination of sufficient cool and fresh air is required.
Dimensions and weight
Dimensions
Recommended
optimum
operating range
Limit of
operation
Limit value with High
Temperature Kit
(optional)
Temperature
18°C to 24°C
10°C to 32°C
up to 35° C (95° F) max.
Relative humidity
38 % to 60 %
(Paper: 45 ± 7,5 %)
10% to 80 %
up to 45% max.
Lowest absolute
humidity
2 g/m
3
1 g/m
3
-
Highest absolute
humidity
22 g/m
3
25 g/m
3
18 g/m
3
Simplex printing system
for 50 Hz power
frequency
Simplex printing system for
60 Hz power frequency
Cooling air
7,200 m
3
/h
8,300 m
3
/h
Fresh air
10% - 20% of the cooling air must be fresh air
Air
cleanliness
according to air cleanliness class 2
Height
1,549 mm (60.3 ")
Length
2,316 mm (90 ")
Depth
1,060 mm (37 ")
Содержание VarioStream 7000 SINGLE
Страница 1: ...Oc Oc Operating Manual Oc VarioStream 7000 SINGLE Pinfed...
Страница 4: ......
Страница 24: ...1 8 Statutory requirements 24 A29246 X20 X 4 7680 all103 fm...
Страница 44: ...3 2 1 Doors and covers 44 A29246 X20 X 4 7680 fa301 fm Rear view Left door Right door Center door...
Страница 58: ...3 5 Paper feed options 58 A29246 X20 X 4 7680 fa301 fm...
Страница 208: ...6 8 1 Cleaning the toner mark sensor 208 A29246 X20 X 4 7680 fa603 fm...
Страница 354: ...8 6 Permitting or blocking remote access 354 A29246 X20 X 4 7680 fa805 fm...
Страница 373: ...Technical data A29246 X20 X 4 7680 faA01 fm 373 Weight Approx 1 260 kg simplex printing system...
Страница 374: ...Technical data 374 A29246 X20 X 4 7680 faA01 fm...
Страница 384: ......