139
Safety data sheet for the Océ 9800 printer, folder and high capacity
output unit
The contents of this safety data sheet are subject to the disclaimer on page 136
of this manual.
Océ-Bruning
.....a division of Océ-USA, Inc.
1800 Bruning Drive W est
Itasca, Illinois 60143
Number: E-656-a-US-ES
telephone 708-351-2900
Date:
April 1995
This safety data sheet has been compiled to the best of our knowledge as a compact guide to safe handling of this product. W e reserve the right to revise safety data sheets as new
information becomes available. It is the user’s responsibility to determine the suitability of this information for the adoption of safety precautions as may be necessary and to contact the
company to make sure that this sheet is the latest one issued. If and in sofar as limitation of liability is permitted under the applicable laws, we do not accept liability for any inaccuracy
that may occur in this information.
Copyright ©1995 Océ-Nederland B.V.,Venlo, NL
Model
Océ 9800 (p high capacity output unit)
Description
Digital high volume wide format (914 mm) printer
Max. process speed
10 m/min
Dimensions
Width
2965
mm
Depth
1583
mm
Height
1500
mm
Weight
980
kg
Voltage
120/208
V
ϕ
240
V
240/415
V
ϕ
N
Frequency
60
Hz
60
Hz
60
Hz
Current-rated
14-1 1-11
A
22
A
9-4-9
A
Current-max
15-15-15
A
25
A
10-10-10
A
Power consumption, operation
3500
W
Power consumption, standby
1000
W
Mains connection
Cable with plug
Safety class
I
(IEC 536) Protective earth connection
Protection class
IP 20
(IEC 529)
Sound pressure level
At bystander position: standby 44 dB(A); in operation 59 dB(A); impulse
∆
L
i
= 6 dB(A)
Sound power level
Standby 60 dB(A); in operation 75 dB(A)
Radio interference
Complies with FCC rules and regulations, part 15 class A
Radiation
Below the Threshold Limit V
alue for UV radiation (TL V list of ACGIH)
Heat emission
Standby 1000 W ; in operation 3500 W
Ozone emission
0,01 mg/min at continuous operation
Room volume
Recommendation: min. 75 m
3
Room ventilation
Recommendation: min. 37,5 m
3
/h (natural ventilation)
For heat evacuation extra ventilation may be necessary
Use simulation at random
operation
Room volume and ventilation as recommended
Daily copy volume (much more than average
)
900
m
2
Total worktime
8
h
Ozone concentrations:
- Time weighted average
0,001
mg/m
3
(0,0005
ppm)
- Peak
0,002
mg/m
3
(0,001
ppm)
Threshold Limit V alue/Occupational Exposure Limit
(Time W eighted A verage) for ozone
0,2
mg/m 3
(0,1
ppm)
Odour Perception Limit for ozone
0,04
mg/m 3
(0,02
ppm)
Consumables
Océ 9800 OPC (Océ Safety Data Sheet E-194)
Océ 9800 T oner (Océ Safety Data Sheet E-179)
Océ Copying Materials
Marking
Listed according to standard UL 1950
Listed according to standard
CAN/CSA-C22.2 No. 950
Additional safety information
The ozone filter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m
3
(the life of the filter equals that of the copier)
Содержание 9800
Страница 1: ...Oc 9800 Printer User Manual...
Страница 6: ...6 Oc 9800 Printer User Manual...
Страница 37: ...Using the Oc 9800 Printer 37...
Страница 38: ...38 Oc 9800 Printer User Manual...
Страница 60: ...60 Oc 9800 Printer User Manual...
Страница 74: ...74 Oc 9800 Printer User Manual...
Страница 88: ...88 Oc 9800 Printer User Manual...
Страница 118: ...118 Oc 9800 Printer User Manual...
Страница 119: ...119 Oc 9800 Printer User Manual Appendix A Overviews...
Страница 130: ...130 Oc 9800 Printer User Manual...
Страница 131: ...131 Oc 9800 Printer User Manual Appendix B Safety information...
Страница 141: ...141 Oc 9800 Printer User Manual Appendix C Miscellaneous...
Страница 148: ...148 Oc 9800 Printer User Manual...