UM10375
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
User manual
Rev. 3 — 14 June 2011
244 of 368
NXP Semiconductors
UM10375
Chapter 13: LPC13xx I2C-bus controller
5. Set up Master Receive mode data buffer.
6. Initialize Master data counter.
7. Exit
13.12.5.4 State: 0x10
A Repeated START condition has been transmitted. The Slave A R/W bit will be
transmitted, an ACK bit will be received.
1. Write Slave Address with R/W bit to I2DAT.
2. Write 0x04 to I2CONSET to set the AA bit.
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Set up Master Transmit mode data buffer.
5. Set up Master Receive mode data buffer.
6. Initialize Master data counter.
7. Exit
13.12.6 Master Transmitter states
13.12.6.1 State: 0x18
Previous state was State 8 or State 10, Slave A Write has been transmitted, ACK
has been received. The first data byte will be transmitted, an ACK bit will be received.
1. Load I2DAT with first data byte from Master Transmit buffer.
2. Write 0x04 to I2CONSET to set the AA bit.
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Increment Master Transmit buffer pointer.
5. Exit
13.12.6.2 State: 0x20
Slave A Write has been transmitted, NOT ACK has been received. A STOP
condition will be transmitted.
1. Write 0x14 to I2CONSET to set the STO and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
13.12.6.3 State: 0x28
Data has been transmitted, ACK has been received. If the transmitted data was the last
data byte then transmit a STOP condition, otherwise transmit the next data byte.
1. Decrement the Master data counter, skip to step 5 if not the last data byte.
2. Write 0x14 to I2CONSET to set the STO and AA bits.
3. Write 0x08 to I2CONCLR to clear the SI flag.
4. Exit
5. Load I2DAT with next data byte from Master Transmit buffer.