8.2.1.1. Battery Cell Connector for Cell Interface - 12 channel
Table 21. Cell Interface - 12 channel Battery Cell Connector Pin Assignment
Pin
Connection
Description
Connected to Device
1
CELL0
Bottom reference of Cell Interface
Connect to negative terminal of the lowest cell
(Cell 1)
2
CELL2
Cell 2 voltage sense
Connect to positive terminal of Cell 2
3
CELL4
Cell 4 voltage sense
Connect to positive terminal of Cell 4
4
CELL6
Cell 6 voltage sense
Connect to positive terminal of Cell 6
5
CELL8
Cell 8 voltage sense
Connect to positive terminal of Cell 8
6
CELL10
Cell 10 voltage sense
Connect to positive terminal of Cell 10
7
CELL12
Cell 12 voltage sense
Connect to positive terminal of Cell 12
8
No Connect
Not Connected
No Connect
9
No Connect
Not Connected
No Connect
10
CELL1
Cell 1 voltage sense
Connect to positive terminal of the lowest cell (Cell
1)
11
CELL3
Cell 3 voltage sense
Connect to positive terminal of Cell 3
12
CELL5
Cell 5 voltage sense
Connect to positive terminal of Cell 5
13
CELL7
Cell 7 voltage sense
Connect to positive terminal of Cell 7
14
CELL9
Cell 9 voltage sense
Connect to positive terminal of Cell 9
15
CELL11
Cell 11 voltage sense
Connect to positive terminal of Cell 11
16
No Connect
Not Connected
No Connect
17
No Connect
Not Connected
No Connect
18
No Connect
Not Connected
No Connect
8.2.1.2. Battery Cell Connector for Cell Interface - 16 channel
Table 22. Cell Interface - 16 channel Battery Cell Connector Pin Assignment
Pin
Connection
Description
Connected to Device
1
CELL0
Bottom reference of Cell Interface
Connect to negative terminal of the lowest cell
(Cell 1)
2
CELL2
Cell 2 voltage sense
Connect to positive terminal of Cell 2
3
CELL4
Cell 4 voltage sense
Connect to positive terminal of Cell 4
4
CELL6
Cell 6 voltage sense
Connect to positive terminal of Cell 6
5
CELL8
Cell 8 voltage sense
Connect to positive terminal of Cell 8
6
CELL10
Cell 10 voltage sense
Connect to positive terminal of Cell 10
7
CELL12
Cell 12 voltage sense
Connect to positive terminal of Cell 12
8
CELL14
Cell 14 voltage sense
Connect to positive terminal of Cell 14
9
No Connect
Not Connected
No Connect
10
CELL1
Cell 1 voltage sense
Connect to positive terminal of the lowest cell (Cell
1)
11
CELL3
Cell 3 voltage sense
Connect to positive terminal of Cell 3
12
CELL5
Cell 5 voltage sense
Connect to positive terminal of Cell 5
13
CELL7
Cell 7 voltage sense
Connect to positive terminal of Cell 7
14
CELL9
Cell 9 voltage sense
Connect to positive terminal of Cell 9
15
CELL11
Cell 11 voltage sense
Connect to positive terminal of Cell 11
Nuvation Energy High-Voltage BMS - Product Manual
Document ID: NE-PM-003
76
Rev 1.2, 2021-03-03
Curie Update 1