12.4 On-Board USB Port:
Uploading Service Performance/Event Data:
Refer to STB0348
Uploading Incubator Programming:
Refer to PTB0347
When connecting external accessories or components to the system,
attach only components that have been tested and certified for
compliance to UL/IEC 60601-1 or UL/IEC 60950
13.0 Electrical/Environmental Requirements
13.1 Electrical
Models: NU-5710, NU-5720, NU-5731 and NU-5741
Domestic Units:
115V, 50/60Hz,
1 Phase,
8.5 Amps
“E” Units:
230V, 50/60Hz,
1 Phase,
4.3 Amps
Start Up Power
475 Watts
Running Power
200 Watts
Decon Cycle
750 Watts
13.2 Operational Performance (for indoor use only)
Environment Temperature Range:
60
°
F-85
°
F (15.5
°
C – 29.4
°
C)
Environment Humidity:
Maximum relative humidity 80% for temperatures up to
31°C decreasing linearly to 50% relative humidity at 40°C
Environment Altitude:
6562 ft (2000 m) over sea level maximum
13.3 Light Exposure
Standard Fluorescent Lighting @ 150 ft. candles (1614 LUX) maximum intensity.
13.4 Installation Category:
2.0
Installation category (overvoltage category) defines the level of transient overvoltage, which the instrument is designed
to withstand safely. It depends on the nature of the electricity supply and its overvoltage protection means. For
example, in CAT II, which is the category used for instruments in installations supplied from a supply comparable to public
mains such as hospital and research laboratories and most industrial laboratories, the expected transient overvoltage is
2500V for a 230V supply and 1500V for a 120V supply.
13.5 Pollution Degree:
2.0
Pollution degree describes the amount of conductive pollution present in the operating environment. Pollution degree
2.0 assumes that normally only non-conductive pollution such as dust occurs with the exception of occasional
conductivity caused by condensation.
13.6 Chemical Exposure
Chemical exposure should be limited to antibacterial materials used for cleaning and disinfecting. Chlorinated and
Halogen materials are not recommended for use on stainless steel surfaces. Chamber decontamination can be
accomplished by paraformaldehyde, vapor phased Hydrogen Peroxide or Ethylene Oxide without degradation of cabinet
materials.
13.7 EMC Performance (classified for light industrial)
Emissions:
EN61326
Immunity:
EN61326
Class A equipment is intended for use in an industrial environment.
In the documentation for the user, a statement shall be included drawing
attention to the fact that there may be potential difficulties in ensuring
electromagnetic compatibility in other environments, due to conducted
as well as radiated disturbances.
CAUTION
!
WARNING
!
Содержание NU-5710
Страница 9: ...OM0249 Page 9 of 64 Rev 4 June 2020 ...
Страница 13: ...OM0249 Page 13 of 64 Rev 4 June 2020 ...
Страница 24: ...OM0249 Page 24 of 64 Rev 4 June 2020 ...
Страница 26: ...OM0249 Page 26 of 64 Rev 4 June 2020 ...
Страница 58: ...OM0249 Page 58 of 64 Rev 4 June 2020 ...
Страница 59: ...OM0249 Page 59 of 64 Rev 4 June 2020 ...
Страница 60: ...OM0249 Page 60 of 64 Rev 4 June 2020 ...
Страница 61: ...OM0249 Page 61 of 64 Rev 4 June 2020 ...
Страница 62: ...OM0249 Page 62 of 64 Rev 4 June 2020 ...
Страница 63: ...OM0249 Page 63 of 64 Rev 4 June 2020 ...
Страница 64: ...OM0249 Page 64 of 64 Rev 4 June 2020 ...