![Nu-Flame The Icona 600 H.E. Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/nu-flame/the-icona-600-h-e/the-icona-600-h-e_use-installation-and-servicing-instructions_1715503022.webp)
22
i.
The Inner Base of the Builders Enclosure must be at least 180mm below the base of the cut out to cater for the sunken Burner
System.
j.
The Enclosure Opening must be level and between 580mm to 610mm wide and 330mm to 350mm high as shown above.
k.
A flat area must be left around the opening to cater for the Trim/Frame Style ordered and allowance will be required for any Fire
Surround Back Panel or Slips. You will also need to cater for a border around the outside of the trim.
The Flat Area Sizes Required are shown below for each Trim/Frame. Also the typical sizes with a 100mm border are shown below.
Minimum Flat Sizes for Trims 100mm Border Plus Minimum Flat Sizes for Trims
Width (mm) Height (mm) Width (mm) Height (mm)
Harmony Trim 670mm 425mm 870mm 625mm
Deluxe Trim 770mm 525mm 970mm 725mm
Grande Trim 1025mm 880mm 1225mm 880mm
Concept Trim 700mm 425mm 970mm 625mm
l.
If a Fire Surround is being considered it may have to be Purpose Made and designed see
. l .
m.
Slate or Marble Fire Surrounds or Slips and/or any adhesives used must have a 150 Degree Centigrade rating. Care should be
taken with Micro Marbles claiming to have a 150Centigrade Rating as they can suffer from odour, blistering and discolouration.
A Fire Surround consisting of both Combustible and Non Combustible materials can be used, however the following applies:
.
The Lower Shelf or Hearth below the fire Must always be Non-Combustible.
.
The Upper Shelf or Mantel above the fire can be either Combustible or Non Combustible, however for Combustible it Must be
positioned 150mm above the Enclosure Opening for shelves up to 150mm deep and raised 25mm for every 25mm of extra
depth.
.
Any side members of the Fire Surround can be either Combustible or Non Combustible, however for Combustible they Must be
at least 100mm from the Enclosure Opening for depths of up to 100mm deep and moved a further 25mm for every 25mm of
extra depth.
.
If Non Combustible the Upper Shelf-Top , Sides and Hearth-Base of the Fire Surround can be within 15mm of the Enclosure
Opening.
n.
Any Fire Surround back panel must be fully sealed to the Enclosure Opening after plastering to ensure a good flue seal and have
opening sizes as detailed in
‘ j ‘.
o.
There are no limitations on the depth of Fire Surrounds Shelf/Mantel, for Non Combustible Shelf/Mantels however where they are
deeper than 150mm and below the minimum position of 150mm above the Enclosure opening they will reduce the Radiant Heat.
It is therefore recommended that Natural Materials are used as some Micro Marbles claiming 150 Centigrade Ratings as they can
suffer from odour, blistering and discolouration.
p.
Provided the bottom of the Enclosure Opening is at least 250mm above the floor there is no depth requirements for a Fire
Surround base/hearth.
q.
If the height above the floor to the Enclosure Opening is reduced below the minimum of 250mm the depth of the Fire Surround
base/hearth must be at a minimum of 150mm depth.
r.
The Flue Manufacturers Installation Instructions Must also be followed for this Installation.
s.
The Building Enclosure should have provision for a gas supply as detailed in Section 11 during construction of the Enclosure.
t.
We recommend that the False Chimney Breast is ventilated at both top and bottom to keep the structure cool.
IMPORTANT : The following stages must now be carried out before the front of the False Chimney Breast is fully enclosed.
16.4 - FIXING THE FIREBOX SUPPORT BRACKET ASSEMBLY
We Recommend the use of the Firebox Support Bracket as it is provided to cater for the weight of the Fire when fully
Installed with the Burner Box Assembly and Flue Hood or the Flue Canopy dependant on the type of Installation.
a.
One Support Bracket Assembly is provided with the fire for fixing at the rear of the Builders Enclosure.
The Support Bracket provides adjustment for Building Enclosure depths up to 345mm deep. For deeper Building Enclosures
spacers will be required but they must be made of a non- combustible material..
b.
The top of the Support Brackets should be fixed to the rear of the Builders Opening such that they are level with the base of the
Enclosure Opening.
c.
The fixing should be positioned as shown starting with the lower holes 25mm below the level of the bottom of the Enclosure
Opening and the remaining holes as shown. See diagram.
Содержание The Icona 600 H.E.
Страница 1: ......
Страница 5: ......
Страница 13: ......
Страница 14: ......
Страница 19: ......
Страница 20: ......
Страница 23: ......
Страница 24: ......
Страница 27: ......
Страница 28: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 49: ......