18
BUILDING ENCLOSURE, LINTEL SIZES and FLAT AREA REQUIREMENTS
Important : The Building Enclosure will have to be constructed first allowing for the fire to be built-in prior to the front face, i.e.
Plaster Board being cut out to cover the fire and flanges and provide the Trimless Style.
a.
It is recommended that a qualified builder constructs the building enclosure.
REFERENCE SHOULD BE MADE TO THE DIAGRAMS ON THE PREVIOUS PAGE
b.
It is recommended that lintels are used as detailed in the diagrams above, structural checks may be required.
The diagrams show the maximum sizes of Lintel depth that can be used.
c.
The Building Enclosure must be constructed of Non-combustible materials.
d.
No Combustible materials must be present in the Enclosure.
e.
First determine the preferred bottom position of the Enclosure
Opening, we recommend 500mm but the minimum is 250mm.
f.
If a Wall Mounted Television is being considered then you should
also consult Section 15 as this could determine the preferred
Height position of the Fire and Enclosure Opening.
g.
The inner Base of the Building Enclosure Must be at least 180mm
below the bottom of the Enclosure Opening to cater for the
sunken Burner System.
h.
The Builders Enclosure must be at least 580mm wide to cater for
the Firebox, Burner Box System and Flue Hood or Canopy.
i.
The Enclosure must cater for a minimum depth of 330mm as shown.
j.
The Top of the Builders Opening must be at least 225mm above the
top of the proposed opening or 555mm measured from the
base of the proposed opening to cater for the Hood or Canopy.
k.
A fully sealed Building Enclosure Must be formed with good mortar
joints to ensure the best flue draw is achieved.
l.
A flat area will have to be provided around the Building Enclosure to
ensure the flanges of the Firebox can be sealed, see diagram.
m.
The opening sizes in the Enclosure and Fire Surround Back Panel
must be 575mm wide by 325 high from the base of the Enclosure .
n.
The Building enclosure should have provision for a gas supply as
detailed in Section 11 during construction of the Enclosure.
IMPORTANT: The Firebox will now have to be Built-in to the Building Enclosure before the outer plaster board face is applied
See 15.6
15.5 - FIXING THE FIREBOX SUPPORT BRACKET ASSEMBLY
We Recommend the use of the Firebox Support Bracket as it is provided to cater for the weight of the Fire when fully
Installed with the Burner Box Assembly and Flue Hood or the Flue Canopy dependant on the type of Installation.
a.
One Support Bracket Assembly is provided with the fire for fixing at the rear of the Builders Enclosure.
The Support Bracket provides adjustment for Building Enclosure depths up to 345mm deep. For deeper Building Enclosures
spacers will be required but they must be made of a non- combustible material..
b.
The top of the Support Brackets should be fixed to the rear of the Builders Opening such that they are level with the base of the En-
closure Opening.
c.
The fixing should be positioned as shown starting with the lower holes 25mm below the level of the bottom of the Enclosure Opening
and the remaining holes as shown. See diagram.
Содержание The Icona 600 H.E.
Страница 1: ......
Страница 5: ......
Страница 13: ......
Страница 14: ......
Страница 19: ......
Страница 20: ......
Страница 23: ......
Страница 24: ......
Страница 27: ......
Страница 28: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 49: ......