It is Important that you read the whole Section before proceeding with any Building Work.
12.1 - WALL COVERINGS
With any form of heating appliance convection air will rise up past the fire carrying particles of dust that will in time result in
varying degrees of wall staining. The fire provides an high heat output so we recommend that any wall coverings are best cut back to
within 10mm of the flanges of the fire to reduce the transmitting of temperature through the flanges of the fire.
The Trim will then cover both the Fires flanges and the cut back area of the wall covering.
Over time some staining might occur and we therefore suggest due consideration is taken when considering the use of patterned
paper around the fire.
Due to the heat output of The Icona 600H.E. it is not recommended to use blown vinyl wall covering around the fire.
12.2 - CLEARANCES TO SHELVES & COMBUSTIBLE MATERIALS
a.
A 150mm
non combustible or combustible
shelf can be fitted above the fire but must be positioned at least 150mm above the
builders opening for Trim Styles Harmony, Deluxe, Concept (see Section 8) and at least 180mm for Grande trim style. For deeper
shelves they must be raised a further 25mm for every extra 25mm of depth.
b.
Any combustible sidewall must be at least 275mm from the inside of the Builders/Fireplace Opening.
c.
With all heating appliances, soft furnishings, decorations and wall coverings may discolour or scorch if placed too close.
d.
No combustible material, e.g. curtains must be closer than 500mm to the Builders Opening.
Note : If a shelf is placed to close to the trim or opening it may have an adverse effect on the Trim Finish.
12.3
-
HOLE IN THE WALL BUILDING ENCLOSURE AND OPENING SIZES FOR FIRES WITH TRIMS
REFERENCE SHOULD BE MADE TO THE DIAGRAMS
BUILDING ENCLOSURE and LINTEL SIZES
a.
It is recommended that a qualified builder constructs the building enclosure.
b.
It is recommended that lintels are used as detailed in the diagrams above
structural checks may be required. The diagrams show the maximum sizes of
Lintel depth that can be used.
c.
The Building Enclosure must be constructed of Non-combustible
materials.
d.
No Combustible materials must be present in the Enclosure.
e.
First determine the preferred bottom position of the Enclosure Opening,
we recommend 500mm but the minimum is 250mm.
f.
If a Wall Mounted Television is being considered then you should also
consult Section 15 as this could determine the preferred Height position
of the Fire and Enclosure Opening.
g.
The Base of the Builders Opening must be at least 180mm below the
base of the cut out to cater for the sunken Burner System.
h.
The Builders Opening must be level and between 580mm to 610mm
wide and 330mm to 350mm high as shown above.
i.
The Top of the Builders Opening must extend at least 225mm above the top
of the opening to cater for the Hood or Canopy.
j.
The Enclosure must cater for a minimum depth of 330mm as shown.
k.
A fully sealed Building Enclosure Must be formed with good mortar joints to
ensure the best flue draw is achieved.
12. - INSTALLATION FOR FIRES WITH TRIMS
(Showing Lintel & Shelf Details)
BUILDERS ENCLOSURE REQUIRMENTS
If a Wall Mounted Television is being Considered Also Make Reference to Section 18
Содержание The Icona 600 H.E.
Страница 1: ......
Страница 5: ......
Страница 13: ......
Страница 14: ......
Страница 19: ......
Страница 20: ......
Страница 23: ......
Страница 24: ......
Страница 27: ......
Страница 28: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 49: ......