• With OD sensor (connected to USI)
Requirements:
– OD sensor is installed
–
DP INTERFACE > Material signal
= „On“
Depending on the machine setting, a warning signal or an error message appears:
A) Warning signal
With the setting
DP INTERFACE > Mat. signal stop
= „Off“, if the critical OD is reached, a warning
signal is activated at the USI, which can for example switch a signal lamp. The machine
doesn´t
stop.
B) Error message
With the setting
DP INTERFACE > Mat. signal stop
= „On“, if the critical OD is reached, an error signal
is activated at the USI. The machine stops and the following message appears:
• With OD sensor (connected to AI)
If the critical OD is reached, a warning signal is activated at the USI, which can for example
switch a signal lamp. The machine
doesn´t
stop.
Status num:
5123
USI Material low