Error and Informational Messages
119
no
vd
ocx
(e
n)
6 Ap
ril 20
07
“Unable to open the configuration file from the MAPI session” on page 131
“Unable to open the event log while initializing the gateway” on page 131
“Unable to send Non-Delivery Report while processing inbound message” on page 131
“Unable to set Microsoft Exchange message property while processing outbound message” on
page 131
“Undeliverable message while processing inbound message” on page 132
“Unknown message type while processing inbound message” on page 132
Access to a recipient in the message has been denied while processing inbound
message
Source: GroupWise Exchange Gateway.
Explanation: The sender or the recipient has no access to the gateway.
Action: Verify that the sender or recipient has access to the gateway.
Configuration database not found
Source: GroupWise Exchange Gateway.
Explanation: The gateway home directory is not defined during the gateway startup.
Action: Run the gateway from the gateway home directory or specify the
/home
startup
switch correctly in the
gwexch.cfg
file.
Conversion cleanup error while processing inbound message
Source: GroupWise Exchange Gateway.
Explanation: The gateway is unable to delete the message from the
mts-out
folder of the
gateway mailbox after converting it to a GroupWise message.
Action: Verify that the Microsoft Exchange server is running.
Conversion error while processing inbound message
Source: GroupWise Exchange Gateway.
Explanation: The gateway is unable to spawn a thread to convert a message from Exchange
to GroupWise format.
Possible Cause: Insufficient memory to perform the operation.
Possible Cause: The gateway server might have too many applications running.
Action: Stop some applications or move them to a different server.
Possible Cause: The gateway server might not meet the system memory requirements listed in
Chapter 2, “Exchange Gateway System Requirements,” on page 13
.
Action: Install additional memory.
Conversion initialization error while processing inbound message
Source: GroupWise Exchange Gateway.
Содержание GROUPWISE 7 GATEWAY FOR MICROSOFT EXCHANGE - INSTALLATION AND ADMINISTRATION
Страница 4: ...novdocx en 6 April 2007 ...
Страница 14: ...14 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...
Страница 24: ...24 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...
Страница 54: ...54 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...
Страница 60: ...60 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...
Страница 88: ...88 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...
Страница 142: ...142 GroupWise 7 Gateway for Microsoft Exchange Installation and Administration Guide novdocx en 6 April 2007 ...