7.10. INSTALLING THE LINE CELL
1) If pipe
A
has an outer diameter of 50 mm, cut the
pipe to a length of 248 mm.
If pipe
A
has an outer diameter of 63 mm, cut the
pipe to a length of 232 mm.
2) Fully disassemble the cell following the above
exploded diagram.
3) Rub down all bonding surfaces with sand
paper: pipes
A
, reducers
C
, collars
D
.
4) Slide each nut
B
onto the end of each
pipe
A
.
5) Glue together each set of [pipe
A
-
reducer
C
- collar
D
].
6) Wait for the glue to dry completely.
7) Place each seal
E
inside each collar
D
.
8) Attach cell
F
with the 2 nuts
B
.
7.11. INSTALLATION OF THE T-CELL
1) Fully disassemble the cell following the exploded
diagram above.
2) Rub down all bonding surfaces with sand paper:
pipes
A
, reducers
B
, sleeve
C
.
3) Glue together the unit comprising
[pipes
A
- reducers
B
- sleeve
C
].
4) Wait for the glue to dry completely.
5) Place seal
D
all the way into electrode
E
.
6) Slide electrode
E
into sleeve
C
, with the plates of
the electrode aligned as in the above diagram.
7) Screw nut
F
onto sleeve
C
.
3) Prepare the 2 connectors
17-A
and
17-B
following
the direction of assembly of the parts shown below.
4) Mount the 2 connectors
17-A
/
17-B
and the 2 valves
22
in the 2 saddle clamps
8
in accordance with the
image shown opposite, using Teflon tape.
5) Fix measuring chamber
6
to the wall using the
screws and plastic anchors provided.
6) Connect measuring chamber
6
to the 2 connectors
17-A
and
17-B
, with the semi-flexible tubing
21
cut
to the right size.
7) Remove the
storage vial from ORP probe
19
.
8) Loosen nut
A
(see the image shown opposite)
without removing it.
9) Insert the probe
19
into the measuring chamber
6
as in the photo below.
10) Tighten nut
A
by hand.
ATTENTION
Respect the direction of the arrow engraved on
each fitting.
ATTENTION
Do not invert the connectors
17-A
and
17-B
during assembly: observe the installation
diagram shown on the previous page,
following the direction of the water flow.
ATTENTION
Screw on and tighten nuts
B
by hand.
ATTENTION
Tighten nut
F
by hand.