9.3. KEYPAD
10. MENU STRUCTURE 1
8. COMMISSIONING
→ All of the below steps are to be carried out when
installing the equipment for the first time, and at the
start of each new season.
1) Make sure that the electronics unit is turned off (for
how to do this see the following page).
2) Spread 5 kg of salt* per m3 around the inner edges
of the pool (depending on its volume). * High purity
salt tablets conforming to the EN 16401 standard,
quality A (free of flow agents and anti-caking
agents).
3) Run the filtration pump until the salt poured into the
pool is completely dissolved.
4) Check the water quality parameters and if necessary
make the manual adjustments, following the below
table:
5) Program and switch on the filtration pump using
the table below:
Achieving and maintaining free chlorine levels
between 0.5 and 1 ppm:
6) Measure free chlorine levels with a testing kit.
7) • If free chlorine levels are below 0.5 ppm:
a) Set filtration to „AUTO“.
b) Turn on the electronics unit (for how to do this see
the following page).
c) Set the production value to 100% (for how to do
this see page 23 or 25, depending on the model).
d) Wait until free chlorine levels reach between 0.5
and 1 ppm.
• If free chlorine levels are between 0.5 and 1 ppm:
Turn on the electronics unit ( see the following
page for instructions).
• If free chlorine levels are above 1 ppm:
a) Keep the electronics unit turned off (or turn it
off).|b) Wait until free chlorine levels reach between
0.5 and 1 ppm.
c) Turn on the electronics unit (see the following
page for instructions).
8) Adjust the production setpoint (see page 23 or 25
depending on the model to carry out this operation)
so that the free chlorine level stays between 0.5 and 1
ppm. Several adjustment tests may need to be
carried out, in order to determine an appropriate
value for the production setpoint.
→ Heavy use of the pool, incorrect inclination of the
nozzles of the basin (these must be tilted slightly
downwards), or a tree-filled environment are
decisive factors that strongly influence the free
chlorine level. In this case, increase the production
setpoint, if necessary, to maintain the free chlorine
level between 0.5 and 1 ppm.
9. ELECTRONICS UNIT INTERFACE
9.1. SCREEN
- If display flashing: information awaiting confirmation.
- If display fixed: information confirmed.
9.2. INDICATOR LIGHTS
- Solid green LED: production indicator.
- Flashing red LED: alarm indicator.
ATTENTION
All of the following steps must also be regularly
carried out once the pool is in use.
General visual state
clear, free from algae
or sediment
Temperature
above 15 °C
Potential of hydrogen (pH) between 7.0 and 7.4
Stabilizer levels
(cyanuric acid)
below 30 ppm (mg/l)
Alkali content (AC)
between 80 ppm and
120 ppm
Water hardness (WH)
less than 60°f
Salt levels
5 kg/m
3
(depending on
its volume)
WATER
TEMPERATURE (°C)
HOURS OF FILTRATION
PER DAY (H)
16
8
18
9
20
10
22
11
24
12
26
14
28
17
30
20
>30
24
→ These figures should only be used as a guide.
They should be adjusted if necessary in order to
optimise filtration.
Switching the electronics unit on/off
→ Press and hold this key to turn on and off.
→ Production, with or without ORP
control, starts automatically 2 minutes
after switching on.
→ When turning off, the screen then the
green LED will also turn off.
→ If an alarm has been triggered, first
press on C when turning off.
BOOST BOOST BOOST BOOST BOOST BOOST BOOST BOOST Launches Boost mode.
MENU
MENU
MENU
MENU
MENU
MENU
MENU
MENU Access to the menu structure 2
(see
chapter 11).
C
C
- Back to previous menu.
- Cancels command.
- Browsing the menu structures.
- Command confirmation.
- Browsing the menu structures.
- Value selection.
Com-
mand
key
(reference
pictogram
in this
manual)
Equivalent key
(Each column below corresponds to a keyboard visual)
Function
Display / Navigation
* Initial display by default/upon connection of the unit to a power supply, after a few seconds.