4) With the use of sealing tape (not supplied), screw
the probe connector
16
into the saddle clamp
8
and tighten by hand, as shown in the photo
opposite.
5) Loosen nut
A
without removing it.
6) Insert probe
19
into probe holder
16
as shown in the
image opposite.
7) Tighten nut
A
by hand.
7.9. INSTALLATION OF THE ORP MEASURING HEAT
CONTACTOR (
PRO
MODEL) WITH THE
OPTIONAL MEASURING KIT
1) Mount the 2 saddle clamps
8
on the pipe, as shown
in the image opposite.
2) Drill the top of the pipe through the hole of the
saddle clamps (see arrow opposite), taking care not
to damage the tapping.
3) Check that there are no air bubbles inside the bulb.
If this is not the case, shake the probe by holding the
bulb downwards until the air bubble has risen into the
body of the probe.
4)
Following the image and the instructions shown
opposite:
a) With the use of sealing tape (not supplied), screw
the probe connector
16
into the accessories
holder
15
and tighten by hand.
b) Loosen nut
A
without removing it.
c) Insert pH probe
20
into probe holder
16
.
d) Tighten nut
A
by hand.
7.8. ORP MEASURING HEAT CONTACTOR INSTAL-
LATION (
PRO
) MODEL WITHOUT THE OPTIONAL
MEASURING KIT
1) Mount the saddle clamp
8
on the pipe, as shown in
the image opposite.
2) Drill the top of the pipe through the hole of the
saddle clamp (see arrow opposite), taking care not
to damage the tapping.
3) Remove the
storage vial from ORP probe
19
.
ATTENTION
• Do not push the probe as far as the stop-point
of the pipe. Place the probe halfway up accessories
holder
15
.
• The probe must be installed:
- after the filter and before any treatment device,
- on the top of the pipe,
- vertically, and on the level (not tilted).
ATTENTION
Do not push the probe as far as the stop-point of the
pipe. Place the probe halfway up the pipe.