7.6. INSTALLING THE PH INJECTION HEAT
CONTACTOR (MODELS
DUO
AND
PRO
)
1) Place the pH corrector container
2
as close as
possible to the equipment room’s internal
ventilation and as far away as possible from any
electrical device.
2) Connect the ballasted filter
10
to the peristaltic
pump
13
, with the semiflexible tubing
21
to be cut
to the right size (see photos
A
and
B
).
3) Insert the ballasted filter
10
at the bottom of
container
2
.
4) With the use of Teflon tape (not supplied), screw
the injection connector
18
into the accessories
holder
15
and tighten by hand.
5) Connect the injection connector
18
to the peristaltic
pump
13
, with the semi-flexible tubing,
21
to be cut
as needed.
7.7. I NSTALLING THE PH PROBE (MODELS
DUO
AND
PRO
)
1) Check that the probe bulb is properly immersed in
the solution inside the storage vial.
If this is not the case:
a) Remove the storage vial from the probe (see
photo below), and keep it for wintering.
b) Rinse the bulb with tap water.
c) Soak the probe for 30 minutes in tap water or
in a suitable KCl solution (saturated potassium
chloride).
d) Move directly to stage 3).
2) Remove the
storage vial from the probe, and keep
it for wintering.
7.3. INSTALLING THE ACCESSORIES HOLDER
1) Remove the 5 stoppers and 2 reducers from the
accessories holder.
2) Following the image and instructions shown
opposite, install the accessories holder with or
without the 2 reducers (depending on the diameter
of the pipe).
3) Depending on the elements to be connected to the
accessories holder, screw back up and tighten by
hand the plug(s) required in the accessory holder,
using sealing tape (not supplied).
7.4. INSTALLING THE SALT/TEMPERATURE/
LOW-WATER SENSOR
Screw and tighten by hand the salt/temperature/
water shortage sensor
4
in the accessories holder
15
,
without using sealing tape.
7.5. INSTALLING THE POOL GROUND (OPTIONAL)
The Pool Ground is intended for functional and not
safety purposes. It enables static electricity, whatever
its source may be, to be transferred from the pool
water to the ground. In some cases, static electricity
can stimulate the oxidation of metal parts in contact
with pool water. Static electricity can also disturb the
working of probes, which can lead to the equipment
as a whole not working correctly.
1) Without applying Teflon tape, screw in and tighten
the Pool Ground by hand
14
into the accessories
holder
15
.
2) Connect the pool earthing device
14
to a ground
rod
11
(not supplied) using a copper cable without
isolating sleeve
3
(not supplied).
3) Insert the whole ground rod
11
into the ground.
ATTENTION
• You must comply with the specifications of
installation standards in the country and at the time
of the installation.
• The ground rod should be sited at a distance and
unaffected by any other electrical ground device/rod.
• The ground rod must be at least 1.5 m long.
• The ground into which the ground rod is inserted
should be as wet as possible, and have a resistance
of less than 20 Ω.
ATTENTION
Following image
C
(exploded view of the injection
connector
18
), respect the direction of assembly of
the parts, and in particular the direction of the arrow
engraved on the fitting. Failure to follow these
instructions can lead to the peristaltic pump being
damaged.
ATTENTION
The life of the pH probe depends primarily on the
strict observance of all the instructions provided in
this manual.
ATTENTION
Never touch the bulb of the probe.