NORDAC SK 700E Operating Manual
52
Subject to technical alterations
BU 0700 EN
Removal of the special extension units:
WARNING / NOTE
Installation must be carried out by qualified personnel only, paying particular attention to safety and
warning instructions.
Customer units must not be inserted/removed when live.
1. Switch off the mains voltage, observe the waiting period.
2. Remove the cover grid from the connection area by loosening
the 2 screws and levering out the device cover (slot) or simply
pull it off.
3. Locking lever in the "
open
" position.
4. Using a screwdriver (as shown), lever the customer unit out of its
engaged position and then remove it by hand.
5. Move the locking lever to the "
closed
" position.
6. Replace all covers.
Note:
Following the insertion, replacement or removal of modules, and once the equipment has been switched on again, this
procedure is indicated with the message
E017
Customer unit changed
.
Customer unit
Special extension unit
Customer unit
Special extension unit