NORDAC SK 700E Operating Manual
110
Subject to technical alterations
BU 0700 EN
Display
Error
Cause
¾
Remedy
Group
Detail in
P700 / P701
13.2
Slip error switch-off monitoring
"Safe stop" was carried out
¾
Torque limit (P112) was reached, switch-off or increase as
necessary.
¾
Current limit (P536) was reached, switch-off or increase as
necessary.
¾
Check motor data (motor circuit, stator resistance)
¾
If necessary, check incremental encoder data (P3xx)
E014
14.0
Slave check
PosiCon
- Error 1
Further details can be found in the description
BU 0710
14.1
Host check
14.2
Reference point travel error
14.3
Absolute encoder voltage
monitoring bit
14.4
Absolute encoder error
14.5
Position change and speed do
not match
14.6
Slip error between absolute and
incremental encoders
14.7
Maximum position exceeded
14.8
Minimum position undershot
E015
15.0
Incorrect software version
PosiCon
- Error 2
Further details can be found in the description
BU 0710
15.1
Watchdog PosiCon
15.2
Stack overflow PosiCon
15.3
Stack underflow PosiCon
15.4
Undefined opcode PosiCon
15.5
Protected instruction PosiCon
15.6
Illegal word access PosiCon
15.7
Illegal instruction access PosiCon
15.8
EPROM error PosiCon
E016
16.0
Motor phase error
¾
A motor phase is not connected.
¾
Check P539
E017
17.0
Customer unit change
New or missing customer unit
¾
Switch mains voltage
off
and then
on
again