3.1 Technology unit
(
T
echnology
U
nit, Option)
Technology units are snapped onto the inverter externally. They are for the control or parameterisation of the inverter and for
the display of current operating settings..
Technology unit
(SK TU1-...)
Description
Data
ParameterBox
SK TU1-PAR
For text-driven initialisation, parameterisation, configuration
and control of the frequency inverter. Background illuminated
graphic display.
6 languages
Storage of 5 data sets
Help texts
ControlBox
SK TU1-CTR
Used for commissioning, parameterisation, configuration and
control of the frequency inverter.
4-figure, 7-segment
LED display
Potentiometer
SK TU1-POT
For direct control of the drive from the frequency converter.
Potentiometer 0 to 100%
ON / OFF / Reverse button
CANbus module
SK TU1-CAN
This option enables control of the SK 700E via the CANbus
serial port.
Baud rate: 500 KBit/s
Connector: Sub-D 9
Profibus module
SK TU1-PBR
This option enables control of the SK 700E via the Profibus
DP serial port.
Baud rate: 1.5 MBaud
Connector: Sub-D 9
Profibus module
SK TU1-PBR-24V
This option enables control of the SK 700E via the Profibus
DP serial port. Operation requires an external 24V supply.
Baud rate: 12 MBaud
Connector: Sub-D 9
ext. +24V DC supply
RS 232
SK TU1-RS2
This option enables control of the SK 700E via the RS 232
serial port, e.g. using a PC.
Connector: Sub-D 9
CANopen module
SK TU1-CAO
This option enables control of the SK 700E via the CANbus
serial port, using the CANopen protocol
Baud rate: up to 1 MBit/s
Connector: Sub-D 9
DeviceNet module
SK TU1-DEV
This option enables control of the SK 700E via the DeviceNet
serial port using the DeviceNet protocol.
Baud rate: 500 KBit/s
5-pin screw connector
InterBus module
SK TU1-IBS
This option enables control of the SK 700E via the InterBus
serial port.
Baud rate: 500 kBit/s (2Mbit/s)
Connector: 2 x Sub-D 9
AS interface
SK TU3-AS1
Actuator-sensor interface is a bus system for the lower field
bus level, used for simple control tasks.
4 sensors / 2 actuators 5 / 8 pin
screw connector
Mounting
The technology units must be
installed
as
follows:
1. Switch off the mains voltage,
observe the waiting period.
2.
Remove the blanking cover by
pressing the upper and lower
catches
.
3. Allow the technology unit to engage
audibly by pressing lightly on the
installation surface.
WARNING / NOTE
Modules must not be inserted or removed unless the device is free of voltage. The slots may only be used
for the applicable modules.
Installation of a technology unit
separate from
the frequency inverter is not possible. It must be connected
directly to the frequency inverter.