NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) – Users Manual for Frequency Inverters as Field Distributors
38
BU 0250 en-3021
Pos: 82 /Anleitungen/Elektronik/FU und Starter/2. Montage und Installation/Montage/FDS [SK xxxE-FDS]/Ausstattungsvarianten_03_Konfiguration der Optionsplätze der Anschlussebene_04 [SK 2xxE-FDS] @ 11\mod_1465465471437_388.docx @ 328420 @ 5 @ 1
Area 2, option slots Z1 to Z4
The option slots M1 to M8 are designed for M12 plug connectors. No fixed functions are allocated to
the option slots. Primarily, these option slots are used to connect initiators, an integrated option of type
SK CU4-… . However, if required they can also accept plug connectors for connecting other signal
and control cables.
The mating plug connector is not included in the scope of supply.
As the built-in plug connector cannot be adjusted during assembly, the use of
angled
cable plug
connectors
is not recommended
.
Pos: 83 /Anleitungen/Elektronik/FU und Starter/2. Montage und Installation/Montage/FDS [SK xxxE-FDS]/Steckerbelegung M12-Steckverbinder_03 [SK 2xxE-FDS] @ 38\mod_1569236175313_388.docx @ 2560597 @ @ 1
Function
Plug connector
1)
Option slot
2)
Contact
diagram
Contact assignments
1
2
3
4
5
No.
Colour
DIN1 / DIN2
Socket,
A-coded
24 V
DIN2
GND
DIN1
PE
Z3
black
DIN1
24 V
GND
DIN1
PE
Z3
black
DIN2
24 V
GND
DIN2
PE
Z4
black
AIN1 / AIN2
24 V
AIN2
GND
AIN1
+10 V
Ref
Z1
white
AIN2
24 V
AIN2
GND
+10 V
Ref
Z2
white
AOUT
24 V
AIN2
GND
+10 V
Ref
Z1 - Z4
white
24VO
24 V
GND
Z1 - Z4
black
CAO
(Bus-IN)
Schield
24 V
GND
CAN_H
CAN_L
Z1
gr
DEV
(Bus-IN)
Schield
24 V
GND
CAN_H
CAN_L
Z1
gr
CAO-OUT
(Bus-OUT)
Plug connectors,
A-coded
24 V
GND
CAN_H
CAN_L
Z2
gr
24VI
24 V
GND
Z1 - Z4
black
ETH
(Bus-IN)
Socket,
D-coded
TX+
RX+
TX-
RX-
Z1
green
ETH
(Bus-OUT)
TX+
RX+
TX-
RX-
Z2
green
PBR
(Bus-IN)
Plug connectors,
B-coded
PBR A
PBR B
Z1 / Z2
violet
PBR
(Bus-OUT)
Socket,
B-coded
5 V
PBR A
GND
PBR B
Z2 / Z1
violet
1)
The housing of the plug connectors are internally wired to PE.
2)
If 2 SK CU4-IOE modules are installed, or if an IO module is installed together with an SK CU4-… field bus module, the initiators and
actuators are output via any of the option slots Z1 to Z4. (For detailed information refer to the order confirmation.)
Pos: 85 /Anleitungen/Elektronik/FU und Starter/2. Montage und Installation/Montage/FDS [SK xxxE-FDS]/Steckerbelegung M12-Steckverbinder_04 [SK 2xxE-FDS] @ 38\mod_1569240177538_388.docx @ 2560633 @ @ 1
Содержание NORDAC LINK SK250E-FDS
Страница 211: ...Key word index BU 0250 en 3021 211...
Страница 212: ...6072502 3021...