6 Operating status messages
BU 0250 en-3021
169
12.1
Limit moto./Customer
"Drive switch
-
off limit"
The drive switch-off limit (P534 [-01]) has triggered.
•
Reduce load on motor
•
Set higher value in (P534 [-01]).
12.2
Limit gen.
"Generator switch
-
off limit"
The generator switch-off limit (P534 [-02]) has triggered.
•
Reduce load on motor
•
Set higher value in (P534 [-02]).
12.3
Torque limit
Limit from potentiometer or setpoint source has switched off.
P400 = 12
12.4
Current limit
Limit from potentiometer or setpoint source has switched off.
P400 = 14
12.5
Load monitor
Switch-off due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
•
Adjust load.
•
Change limit values ((P525) ... (P527)).
•
Increase delay time (P528).
•
Change monitoring mode (P529).
12.8
AI minimum
„Analog
ue
In minimum“
Switch-off due to undershooting of the 0% adjustment value
(P402) with setting (P401) "0-10V with switch-off on error 1"
or "....2"
12.9
AI maximum
„Analog
ue
In m
aximum
“
Switch-off due to overshooting of the 100% adjustment
value (P402) with setting (P401) "0-10V with switch-off on
error 1" or "....2"
Pos: 588 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Fehler E013 [SK 200E ... SK 5xxE] @ 2\mod_1347454271218_388.docx @ 46751 @ @ 1
E013
13.0
Encoder error
No signal from encoder
•
Check 5V sensor if present.
•
Check supply voltage of encoder.
13.1
Speed slip error
"Speed slip error"
The slip speed error limit was reached.
•
Increase setting in P327.
13.2
Shut-down monitoring
The slip error monitoring has triggered; the motor could not
follow the setpoint.
•
Check motor data P201-P209! (Important for the
current controller)
•
Check motor circuit.
•
In servo mode, check the encoder setting P300 and
check the following
•
Increase setting value for torque limit in P112.
•
Increase setting value for current limit in P536.
•
Check deceleration time P103 and extend if
necessary
13.5
Reserved
Error message for POSICON
see supplementary
instructions
13.6
Reserved
Error message for POSICON
see supplementary
instructions
Pos: 589 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Fehler E014 "reserviert" [SK 200E ... SK 5xxE/SK 500P] @ 2\mod_1347454273854_388.docx @ 46776 @ @ 1
E014
---
Reserved
Error message for POSICON
see supplementary
instructions
Pos: 590 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Fehler E015 [SK 180E ... SK 5xxE] @ 2\mod_1347454278051_388.docx @ 46801 @ @ 1
E015
---
Reserved
Pos: 591 /Anleitungen/Elektronik/FU und Starter/6. Meldungen zum Betriebszustand/Störmeldungen (Auflistung)/Fehler E016 [SK 135E ... SK 5xxE, SK xxxE-FDS] @ 2\mod_1347454280625_388.docx @ 46826 @ @ 1
E016
16.0
Motor phase error
A motor phase is not connected.
•
Check P539
•
Check motor connection
Содержание NORDAC LINK SK250E-FDS
Страница 211: ...Key word index BU 0250 en 3021 211...