NORDAC LINK (SK 250E-FDS ... SK 280E-FDS) – Users Manual for Frequency Inverters as Field Distributors
130
BU 0250 en-3021
Pos: 405 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P400-P499/Parameter P482 – Normierung Bus I/O Out Bits [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931812166_388.docx @ 42936 @ @ 1
P482
[-01]
...
[-10]
Standard BusIO Out Bits
(Standardisation of Bus I/O Out Bits)
S
-400 … 400 %
{ all 100 }
Adjustment of the limit values of the bus Out bits. For a negative value, the output function will be
output negative.
Once the limit value is reached and positive values are delivered, the output produces a High
signal, for negative setting values a Low signal.
[-01] =
Bus / AS-i Dig Out1
(Bus IO Out Bit 0 + AS-i 1)
[-02] =
Bus / AS-i Dig Out2
(Bus IO Out Bit 1 + AS-i 2)
[-03] =
Bus / AS-i Dig Out3
(Bus IO Out Bit 2 + AS-i 3)
[-04] =
Bus / AS-i Dig Out4
(Bus IO Out Bit 3 + AS-i 4)
[-05] =
Bus / IOE Dig Out1
(Bus IO Out Bit 4 + DO 1 of the
first
SK xU4
-
IOE (DigOut 02))
[-06] =
Bus / IOE Dig Out2
(Bus IO Out Bit 5 + DO 2 of the
first
SK xU4
-
IOE (DigOut 03))
[-07] =
Bus / 2nd IOE Dig Out1
(Flag1 + DO 1 of the
second
SK xU4
-
IOE (DigOut 04))
[-08] =
Bus / 2nd IOE Dig Out2
(Flag2 + DO 2 of the
second
SK xU4
-
IOE (DigOut 05))
[-09] =
Bit 10 BUS status word
[-10] =
Bit 13 BUS status word
Pos: 406 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P400-P499/Parameter P483 – Hysterese Bus I/O Out Bits [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931812868_388.docx @ 42960 @ @ 1
P483
[-01]
...
[-10]
Hyst. BusIO Out Bits
(Hysteresis of Bus I/O Out Bits
)
S
1 … 100 %
{ all 10 }
Difference between switch-on and switch-off point to prevent oscillation of the output signal.
[-01] =
Bus / AS-i Dig Out1
(Bus IO Out Bit 0 + AS-i 1)
[-02] =
Bus / AS-i Dig Out2
(Bus IO Out Bit 1 + AS-i 2)
[-03] =
Bus / AS-i Dig Out3
(Bus IO Out Bit 2 + AS-i 3)
[-04] =
Bus / AS-i Dig Out4
(Bus IO Out Bit 3 + AS-i 4)
[-05] =
Bus / IOE Dig Out1
(Bus IO Out Bit 4 + DO 1 of the
first
SK xU4
-
IOE (DigOut 02))
[-06] =
Bus / IOE Dig Out2
(Bus IO Out Bit 5 + DO 2 of the
first
SK xU4
-
IOE (DigOut 03))
[-07] =
Bus / 2nd IOE Dig Out1
(Flag1 + DO 1 of the
second
SK xU4
-
IOE (DigOut 04))
[-08] =
Bus / 2nd IOE Dig Out2
(Flag2 + DO 2 of the
second
SK xU4
-
IOE (DigOut 05))
[-09] =
Bit 10 BUS status word
[-10] =
Bit 13 BUS status word
NOTE:
Details for the use of the relevant bus systems can be found in the applicable supplementary bus
manual.
Pos: 407 /Allgemein/Allgemeingültige Module/---------Seitenumbruch kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1
Содержание NORDAC LINK SK250E-FDS
Страница 211: ...Key word index BU 0250 en 3021 211...
Страница 212: ...6072502 3021...