5 Parameter
BU 0250 en-3021
155
Pos: 509 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P719 – Aktueller Strom @ 0\mod_1328172979998_388.docx @ 12778 @ @ 1
P719
Actual current
(Actual current)
0.0 ... 999.9 A
Displays the actual output current.
Pos: 510 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P720 – Aktueller Momentstrom @ 0\mod_1328173025780_388.docx @ 12801 @ @ 1
P720
Act. torque current
(Actual torque current)
-999.9 ... 999.9 A
Displays the actual calculated torque-developing output current (active current). Basis for
calculation are the motor data P201...P209.
negative values = generator,
positive values = drive
Pos: 511 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P721 – Aktueller Feldstrom @ 0\mod_1328173074624_388.docx @ 12824 @ @ 1
P721
Actual field current
(Actual field current)
-999.9 ... 999.9 A
Displays the actual calculated field current (reactive current). Basis for calculation are the motor
data P201...P209.
Pos: 512 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P722 – Aktuelle Spannung @ 0\mod_1328173115169_388.docx @ 12847 @ @ 1
P722
Current voltage
(Actual voltage)
0 ... 500 V
Displays the actual AC voltage supplied by the FI output.
Pos: 513 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P723 – Aktuelle Spannungskomponente Ud @ 0\mod_1328173153339_388.docx @ 12870 @ @ 1
P723
Voltage -d
(Actual voltage component Ud
)
S
-500 ... 500 V
Displays the actual field voltage component.
Pos: 514 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P724 – Aktuelle Spannungskomponente Uq @ 0\mod_1328173194227_388.docx @ 12893 @ @ 1
P724
Voltage -q
(Actual
voltage component Uq)
S
-500 ... 500 V
Displays the actual torque voltage component.
Pos: 515 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P725 – Aktueller cos phi @ 0\mod_1328173237475_388.docx @ 12916 @ @ 1
P725
Current Cos phi
(Actual cos
j
)
0.00 ... 1.00
Displays the actual calculated cos
ϕ
of the drive.
Pos: 516 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P726 – Scheinleistung @ 0\mod_1328173288066_388.docx @ 12939 @ @ 1
P726
Apparent power
(Apparent power)
0.00 ... 300.00 kVA
Displays the actual calculated apparent power. The basis for calculation are the motor data
P201...P209.
Pos: 517 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P727 – Mechanische Leistung @ 0\mod_1328173332220_388.docx @ 12962 @ @ 1
P727
Mechanical power
(Mechanical power)
-99.99 ... 99.99 kW
Displays the actual calculated effective power of the motor. Basis for calculation are the motor
data P201...P209.