FORM NO. 56043042 / Whirlamatic
™
2700 / BHS 7014 - 37
ELECTRICAL SYSTEM
ERROR RECALL MODE (ALL MODELS)
If a fault occurs during the operation of the machine, the fault code(s) will be stored for recall at a later time. Only the error code(s) from
the last time the machine was operated will be saved. To enter the error code recall mode perform the following steps:
1
Turn the key switch off
2
Press and HOLD the pad down/on switch while turning the key switch on.
3
Continue to hold the pad down/on switch until the display shows Error (or is scrolling the word ‘SELECT’ on machines after serial
number 1507058). This will take approximately 1.5 seconds.
4
Release the pad down/on switch.
5
For machines before serial number 1507059 go to step 9. For machines after serial number 1507058 go to step 6.
6
The status display should now be scrolling “FAULT RECALL”.
7
Press the pad up switch to enter the fault recall mode. The display will change to “Err x” where x is a letter indicating the revision
level of the control box.
This is not a control error code.
8
Release the pad up switch.
9
If there are no stored error codes the display will show nonE.
10
If there are stored error codes, the codes will appear on the hour meter display. Refer to the troubleshooting guide for further
information.
11
To clear the stored error codes, begin by pressing and releasing the pad down/on switch.
12
The display will now show ErASE.
13
Pressing and releasing the pad down/on switch again will erase the codes. The display will then show nonE.
14
If the pad up/off switch is pressed while the display shows ErASE the display will show the error codes without erasing them.
15
To exit this mode turn the key switch off.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
ERROR CHECKING ENABLE/DISABLE MODE (ALL MODELS)
FACTORY DEFAULT: ON
Normally, the main control unit will perform checks of the electrical system during operation. If a fault occurs in a particular system that
system (and possibly others) will be shut down. This can make troubleshooting the system difficult. This option will allow service personnel
to disable some of the fault detection checks to facilitate troubleshooting. This will not disable the over-current protection on any of the
systems. To enable or disable fault checking:
1
Press and hold pad down switch while turning the key switch on.
2
Continue holding the pad down switch until the status display is scrolling the word “SELECT”.
3
Release the pad down switch.
4
Press and release the pad down switch three times. The status display should now be scrolling “FAULT ENABLE”.
5
Press and release the pad up switch to enter the error checking enable/disable mode.
6
The status display will now show either “ON” or “OFF” depending on whether the error checking is turned on or off.
7
To select the desired option, press and release the pad down switch. This will alternate between the two options.
8
To save the setting and exit this mode turn the key switch off.
revised 2/02
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
SPECIAL PROGRAM OPTIONS