FORM NO. 56043042 / Whirlamatic
™
2700 / BHS 7014 - 33
ELECTRICAL SYSTEM
Error Code
Fault Description
Troubleshooting Action
Err07
Pad motor overload
1. Turn key switch off. 2. Wait for display to go off. 3. Check for
binding in rotation of pad or improper actuator operation. 4. Verify
that 3 position connector on the main board is properly installed.
5. Check negative supply cable to pad motor for wiring problem or
improper modification (this is a special cable and must be re-
placed with the correct APA part). 6. Turn key on to reset.
Err08
Pad motor severe overload
1. Turn key switch off. 2. Wait for display to go off. 3. Check to
see if pad assembly and pad motor turn freely. 4. Check for short
circuit in pad motor or wiring. 5. Check pad motor, if defective
repair or replace. 6. Verify that 3 position connector on the main
board is properly installed. 7. Check negative supply cable to pad
motor for wiring problem or improper modification (this is a special
cable and must be replaced with the correct APA part). 8. Turn key
on to reset.
Err09
Pad motor open circuit (**)
1. Turn key switch off. 2. Wait for display to go off. 3. Check for
disconnected pad motor, open in wiring or defective pad motor. 4.
Verify that 3 position connector on the main board is properly
installed. 5. Check negative supply cable to pad motor for wiring
problem or improper modification (this is a special cable and must
be replaced with the correct APA part). 6. Turn key on to reset.
Err10
Pad motor contactor shorted
1. Check contactor for welded contacts. 2. If welded replace
contactor.
Err11
Pad motor contactor open (**)
1. Turn key switch off. 2. Wait for display to go off. 3. Check wiring
to pad motor. 4. Check contactor for proper operation. 5. If
defective, replace contactor. 6. Turn key on to reset.
Err12
Pad motor contactor coil overload
1. Turn key switch off. 2. Wait for display to go off. 3. Check diode
for continuity in one direction only, if not, replace diode. 4. Check
wiring, if OK, replace contactor. 5. Turn key on to reset.
Err13
Pad motor contactor coil severe overload
1. Turn key switch off. 2. Wait for display to go off. 3. Check diode
for continuity in one direction only, if not, replace diode. 4. Check
wiring, if OK, replace contactor. 5. Turn key on to reset.
Err14
Pad motor contactor coil open (**)
1. Turn key switch off. 2. Wait for display to go off. 3. Check for
open in wiring. 4. If OK, replace contactor. 5. Turn key on to reset.
Err17
Pad motor cable thermistor failure
Machine exposed to a very cold or hot operating temperature.
Allow machine to be warmed or cooled to room temperature.
Temp range 32
º
F to 185
º
F (0 to 85
º
C) 2. Cable failure, replace
the brush motor negative cable assembly (this is a special cable
and must be replaced with an original APA part). Note: Machine
will still operate if error persists, replace.
Service Tip: When troubleshooting the main controller, always check all the wiring connected to the controller for any possible damage.
Damage to the wiring insulation could allow current leakage to any metal found in the electrical panel assembly and cause numerous
control system faults.
revised 2/02
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
MAIN CONTROL ERROR CODES BEFORE SN 1507059 (CONTINUED)