21
04 - Control System
– Vac motors M4 and M5 – Wand mode (seat switch open upon entry) or Squeegee Actuator M6
◦
No recovery system fault (vac motors and squeegee)
◦
No Estop inhibit
◦
No impact lockout inhibit
◦
No low voltage cut out inhibit (second stage)
◦
No RTF inhibit
◦ Note M5 also requires Vacuum option set to dual in the configuration menu
•
Solution System Outputs
– Solution Solenoid L1 –
◦
Scrub system active
◦
No solution solenoid fault
◦
No recovery system fault (vac motors and squeegee)
◦
Throttle command not equal to zero
◦
No Estop inhibit
◦
No impact lockout inhibit
◦ No low voltage cut out inhibit (first or second stage)
◦
No RTF inhibit
◦
Not turned off with the membrane switch
◦
Not momentarily turned off by the solution timed off paddle switch input
– Spray wash pump M10
◦
No spray wash pump M10 fault
◦
Solution tank is not empty
◦ Option (Opt) pump in configuration menu set to “Spray Wash”
•
Detergent System outputs
– Detergent Pumps M8 and M9
◦
Solution system is active
◦ EcoFlex is enabled in the configuration menu
◦
Not turned off with the control panel detergent switch
•
Side Sweep System Outputs
– Side Sweep Motor M3
◦
No sweep motor M3 fault
◦
Scrub brushes active
◦ Side Sweep set to “yes” in the configuration menu
◦
Side Sweep switch open
– Dust Guard Pump M10
◦
No dust guard solenoid L2 fault
◦
No option pump M10 fault
◦
Side sweep motor active
◦
Solution tank is not empty
◦ Option (Opt) pump in configuration menu set to “Dust Guard”
◦
No Estop inhibit