CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications ............................................ 1-1
[2] Operation panel ......................................... 1-2
[3] Transmittable documents .......................... 1-3
[4] Installation ................................................. 1-4
[5] Quick reference guide ............................... 1-7

CHAPTER 2. ADJUSTMENTS
[1] Adjustments ............................................... 2-1
[2] Diagnostics and service soft switch .......... 2-2
[3] Troubleshooting ......................................  2-17
[4] Error code table ....................................... 2-18

CHAPTER 3. MECHANISM BLOCKS
[1] General description ..................................  3-1
[2] Disassembly and assembly
              procedures ....................................... 3-3

CHAPTER 4. DIAGRAMS
[1] Block diagram ............................................ 4-1
[2] Wiring diagram .......................................... 4-2
[3] Point-to-point diagram ............................... 4-3

CHAPTER 5. CIRCUIT DESCRIPTION
[1] Circuit description ...................................... 5-1
[2] Circuit description of control PWB ..............5-2
[3] Circuit description of TEL/LIU PWB .......... 5-8
[4] Circuit description of
            power supply PWB ............................ 5-11
[5] Circuit description of CIS unit ................... 5-11

CHAPTER 6. CIRCUIT SCHEMATICS AND
PARTS LAYOUT
[1] Control PWB circuit ................................... 6-1
[2] TEL/LIU PWB circuit ................................. 6-9
[3] Power supply PWB circuit .......................  6-11
[4] Operation panel PWB circuit ................... 6-13

CHAPTER 7. OPERATION FLOWCHART
[1] Protocol ..................................................... 7-1
[2] Power on sequence .................................. 7-2

CHAPTER 8. OTHERS
[1] Service tools .............................................. 8-1
[2] IC signal name .......................................... 8-3
PARTS GUIDE

CONTENTS

FACSIMILE

UX-178

UX-188

UX-108

UX-118

FO-175

 

MODEL 

FO-375

Parts marked with "

" is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for

maintaining the safety and performance of the set.

This document has been published to be used
for after sales service only.
The contents are subject to change without notice.

SHARP CORPORATION

SERVICE MANUAL

Non Cutter model

Cutter model

UX-108/118

UX-178/188

FO-175

FO-375

Illustration: UX-178

Содержание FO-175

Страница 1: ...uit description of power supply PWB 5 11 5 Circuit description of CIS unit 5 11 CHAPTER 6 CIRCUIT SCHEMATICS AND PARTS LAYOUT 1 Control PWB circuit 6 1 2 TEL LIU PWB circuit 6 9 3 Power supply PWB circuit 6 11 4 Operation panel PWB circuit 6 13 CHAPTER 7 OPERATION FLOWCHART 1 Protocol 7 1 2 Power on sequence 7 2 CHAPTER 8 OTHERS 1 Service tools 8 1 2 IC signal name 8 3 PARTS GUIDE CONTENTS FACSIMI...

Страница 2: ...sto valmistajan ohjeiden mukaisesti French ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Remplacer uniquement avec une batterie du même type ou d un type recommandé par le constructeur Mettre au rébut les batteries usagées conformément aux instructions du fabricant Swedish VARNING Explosionsfare vid felaktigt batteribyte Använd samma batterityp eller en ekvival...

Страница 3: ...er Compression scheme MH MR Sharp Scanning method Sheet feeder CIS Contact Image Sensor Effective recording width 210 mm 8 3 max Input document size Automatic feeding Width 148 to 216 mm 5 8 to 8 5 Length 140 to 279 mm 5 5 to 11 Manual feeding Width 148 to 216 mm 5 8 to 8 5 Length 140 to 600 mm 5 5 to 23 6 Effective scanning width 210 mm 8 3 max Contrast control Automatic Dark selectable Copy func...

Страница 4: ...d or the volume of the ringer at all other times 7 STOP key Press this key to stop operations before they are completed 8 Number keys Use these keys to dial numbers and enter number and letters during number name storing procedures 9 SPEED DIAL key Press this key to dial a 2 digit Speed Dial number 10 REDIAL key Press this key to automatically redial the last number dialed 11 SPEAKER key Press thi...

Страница 5: ...to prevent possible double feeds Normal size width 148 216 mm length 140 279 mm 5 Automatic Document Feeder Capacity Number of pages that can be placed into the feeder at anytime is as follows Normal size max ADF 10 sheets Special size single sheet only manual feed NOTES When you need to send or copy more pages than the feeder limit place additional pages in feeder when last page in feeder is bein...

Страница 6: ...If the machine is moved from a cold to a warm place If the machine is moved from a cold to a warm place it is possible that the reading glass may fog up preventing proper scanning of documents for transmission To remove the fog turn on the power and wait approxi mately 2 hours before using the machine TELEPHONE JACK A standard RJ11C telephone jack must be located near the machine This is the telep...

Страница 7: ...er into the paper inlet Continue to push the paper through the inlet until it comes out of the opening in the front of the fax 6Close the operation panel making sure it clicks into place 7UX 108 118 FO 175 A short length of the fax paper will feed out Grasp the paper by the edge and pull upward to tear it off UX 178 UX 188 FO 375 A short length of the fax paper will feed out and be cut off If this...

Страница 8: ...cutter 3Cut off the wrinkled part of the paper 4Reload the paper Jammed fax paper is often caused by improper loading Be sure to carefully follow the instructions for paper loading given in Load ing the Fax Paper in page 1 5 5If the display still shows PAPER JAMMED UX 178 188 FO 375 only If the display still shows PAPER JAMMED after you press theSTART key in Step 2 above the cutter is still engage...

Страница 9: ...12 Enter two digits for the Minute 00 through 59 Press the key for A M or the key for P M When finished press STORING AND CLEARING NUMBERS FOR AUTO DIALING 1 Press Display shows FAX TEL MODE 2 Press 1 to store a number or 2 to clear a number 3 Enter a 2 digit Speed Dial number from 01 to 10 for Rapid Key Dialing or 11 to 30 for Speed Dialing If you are clearing a number go to Step 7 4 Enter the fu...